SmartOne AlarmLine Installation, Operation And Maintenance Manual Download Page 1

Manual Number: 73.04

Part Number: 06-235820-001

Effective: March 2001

AlarmLine™

Addressable

Linear Heat Detector

Installation, Operation,

and Maintenance

Manual

R

LISTED

The AAM is Listed as a System
Control Unit Accessory.
The Sensor Cable is Listed as a
Heat Automatic Fire Detector.

Summary of Contents for AlarmLine

Page 1: ...20 001 Effective March 2001 AlarmLine Addressable Linear Heat Detector Installation Operation and Maintenance Manual R LISTED The AAM is Listed as a System Control Unit Accessory The Sensor Cable is L...

Page 2: ......

Page 3: ...ALARMLINE LINEAR HEAT DETECTOR Installation Operation and Maintenance Manual...

Page 4: ...THIS PAGE INTENTIONALLY LEFT BLANK...

Page 5: ...3 2 1 Selecting Module Location 7 3 2 2 Installing the Back Box or NEMA 4 Enclosure 7 3 2 2 1 Back Box Installation 7 3 2 2 2 NEMA 4 Enclosure Installation 7 3 2 3 Wiring the AAM 8 3 3 Intrinsic Safe...

Page 6: ...yer 14 8 5 1 Overhead Installation 14 8 5 2 Roller Idler Arm Installation 15 8 6 Floating Roof Fuel Tank 15 8 7 Cooling Tower 15 8 8 Dust Collector 15 8 9 Waste Fuel Drum Storage 16 8 10 Power Distrib...

Page 7: ...d the predicted alarm set point can be shifted higher than anticipated or may not cause a response on the AlarmLine module At one end of the sensor cable the conductors are spliced to form two loops S...

Page 8: ...s e r o t s e R 7 5 2 o 5 2 1 F o C e v o b A 4 7 3 o 0 9 1 F o s i C e v i t c u r t s e d e h t e r u t a r e p m e t 2 1 2 o t p U o F 0 0 1 o 0 3 C 7 5 2 s r a e Y o F 5 2 1 o 4 2 C f l e S s r u...

Page 9: ...r a given set point is established by the use of a nomogram incor porating two known factors Maximum ambient temperature of the alarm zone Length of the sensor cable The integrating averaging effect o...

Page 10: ...C mark on Scale A The line crosses Scale S at approximately configuration Setting 11 2 Setting11wouldthereforebeselectedandprogrammed for the module s configuration After determining the alarm settin...

Page 11: ...nylon cable clamp will fit in a 1 4 mounting hole MASTER CLAMP The Master Clamp P N 73 117068 022 for a box of 100 is a multipurpose fastener that fits all beam flanges up to 1 2 13 mm thick and resis...

Page 12: ...10 for correct crimping procedures slide the tub ing into place over the four splices and heat shrink using an appropriate hot air gun This provides both insulation and strain relief When heat shrink...

Page 13: ...one to accommodate testing of the sensor by a hot air gun 5 4 1 2 Figure 12 Heat Pad HEAT PAD Figure 13 Bearing Plate Installation 3 2 Installing the Addressable AlarmLine Module AAM 3 2 1 SELECTING M...

Page 14: ...onnect wiring to proper terminals on TB1 and TB2 of AAM 10 Using two 8 32 screws provided mount AAM to bracket Tinnerman nuts 11 Install enclosure cover noting that cover index tab must align with mat...

Page 15: ...on the module Refer to the FenwalNET 2000 Installation Operations and Maintenance Manual P N 74 100016 001 or the Kidde PEGAsys Installation Operations and Main tenance Manual P N 76 100016 001 for R...

Page 16: ...4 CONFIGURATION There are two ways in which the AAM can be config ured 1 Using the panel s configuration software Refer to the FenwalNET Configuration Software FCS Manual 74 225 or the PEGAsys Config...

Page 17: ...the display reads SET AMM CONFIGURATION LEVELS SET ON 1 DETECTORS 13 The CCM display should now return to SYSTEM STATUS NORMAL 6 REPORTING 6 1 Status Reporting In response to commands sent from the c...

Page 18: ...sarm any extinguishing alarm or other auxiliary functions connected to the interface module and the fire control panel Because Fire and Fault test conditions are signaled to the control panel like gen...

Page 19: ...er all cables in a tray and should be fastened to alternating sides of the tray as shown with mount ing hardware For indoor applications use standard PVC sensor P N 73 117068 013 For outdoor appli cat...

Page 20: ...sensor cable support 8 4 Freezer Warehouse CAUTION While the nylon AlarmLine sensor is rated for operation down to 40 F 40 C special care must be taken during the installation process Because the cond...

Page 21: ...a means for preventing entanglement of the cable during travel NOTE Intrinsic safety barriers should be used for this application OUTER TANK WALL ALARMLINE SENSOR TOP VIEW SIDE VIEW CUT AWAY ALARMLIN...

Page 22: ...DED ALARMLINE SENSOR JUNCTION BOX WITH STRAIN RELIEF FITTING Figure 28 Drum Storage Overhead Installation Top View ALARMLINE SENSOR 55 GALLON DRUM SELF ADHESIVE MOUNTING HARDWARE 2 Figure 29 Drum Stor...

Page 23: ...U 6 2 0 8 6 0 7 1 1 3 7 d e t a o C n o l y N h t i w d e s u r o t c e n n o C t h g i t r e h t a e W r o s n e S d e d i a r B e z n o r B r o 7 2 0 8 6 0 7 1 1 3 7 0 1 f o g k P e c i l p S r o s...

Page 24: ...18 March 2001 06 235820 001 AlarmLine Addressable Linear Heat Detector THIS PAGE INTENTIONALLY LEFT BLANK...

Page 25: ...20 115 105 95 95 105 115 120 130 140 165 175 185 210 220 230 257 3 5 10 20 25 35 50 65 80 100 130 165 200 230 265 300 500 650 825 1000 1300 1650 2000 2300 2600 2900 3200 250 240 205 195 160 150 85 75...

Page 26: ...20 March 2001 06 235820 001 AlarmLine Addressable Linear Heat Detector THIS PAGE INTENTIONALLY LEFT BLANK...

Page 27: ...5 65 60 55 50 45 40 35 35 40 45 50 55 60 75 80 85 100 105 110 125 1 1 5 3 6 8 10 15 20 25 30 40 50 60 70 80 90 150 200 250 300 400 500 600 700 800 900 1000 120 115 95 90 70 65 30 24 70 15 14 13 12 11...

Page 28: ...22 March 2001 06 235820 001 AlarmLine Addressable Linear Heat Detector THIS PAGE INTENTIONALLY LEFT BLANK...

Page 29: ...OR REV DATE 5 SYSTEM EQUIPMENT 6 PRIORITY OF COMMENT 7 USER EVALUATION MANUAL IS q EXCELLENT q GOOD q FAIR qPOOR q COMPLETE q INCOMPLETE 8 q PROBLEM qQUESTION q SUGGESTION q COMMENT check one 9 RECOM...

Page 30: ...KIDDE FENWAL Inc 400 Main Street Ashland MA 01721 Attn Documentation Manager Place Stamp Here FOLD FOLD...

Page 31: ......

Page 32: ...thorization RMA number before returning material to the factory at Ashland Massachusetts shipment prepaid Kidde Fenwal will repair or replace and ship prepaid PEGAsys FenwalNET and AlarmLine are all t...