background image

“A division of NESS CORPORATION PTY LTD”

© Copyright SmartLink

November 2013

Unit 4/56 Norcal Rd,

Nunawading VIC 3131 Australia

Tel: +61 3 9875 6400

Facsimile: +61 3 9875 6422

Email: [email protected]

Web Site: www.smartlink.com.au

Smartlink Medi-Link GPRS/GSM Installation Manual Rev1.30

Document Part Number:

890-438

For products:

100-824 Medi-Link GPRS/GSM Unit
100-825 Medi-Link 3G Unit
100-827 Medi-Link 3G + PSTN Unit

© 2012 Ness Corporation Pty Ltd ABN 28 069 984 372
Specifications may change without notice.

Ness Corporation manufacturing processes are accredited to ISO9001 quality standards and all possible care and diligence has been
applied during manufacture to ensure the reliable operation of this product. However there are various external factors that may
impede or restrict the operation of this product in accordance with the product’s specification.
These factors include, but are not limited to:
1. Erratic or reduced radio range. Ness radio products are sophisticated low power devices, however the presence of in-band radio
signals, high power transmissions or interference caused by electrical appliances such as wireless routers, cordless phones,
computers, TVs and other electronic devices may reduce the range performance. While such occurrences are unusual, they are
possible. In this case it may be necessary to either increase the physical separation between the Ness receiver and other devices or if
possible change the radio frequency or channel of the other devices.
2. Unauthorised tampering, physical damage, electrical interruptions such as mains failure, electrical spikes or lightning.

Summary of Contents for Medi-Link 100-824

Page 1: ...MEDI LINK GPRS GSM INSTALLATION MANUAL Medi Link GPRS GSM Installation Manual Rev1 30 Part No 100 824 Part No 100 825 Part No 100 827 ...

Page 2: ... this product However there are various external factors that may impede or restrict the operation of this product in accordance with the product s specification These factors include but are not limited to 1 Erratic or reduced radio range Ness radio products are sophisticated low power devices however the presence of in band radio signals high power transmissions or interference caused by electri...

Page 3: ...Link GPRS GSM Unit 7 9 1 To Enter Program Mode 7 9 2 Programming CLIENT ACCOUNT 7 9 3 Programming PHONE NUMBERS GSM If Required 7 9 4 Programming SERVER GPRS If Required 8 9 5 Programming SYSTEMS 8 9 6 Programming CELLULAR 9 9 7 Programming REPORTS 10 9 8 To EXIT PROGRAM Mode 10 10 Signal Quality Strength 11 11 Setting the Time and Date 11 12 Up Download Programmer Software 12 13 Medi Link UDP SER...

Page 4: ...S GSM unit uses a Cellular Module to report using the mobile network The Cellular Module requires a SIM to connect to a particular network The SIM itself has various attributes that can be set by the network provider Some of these options are available for Medi Link GPRS GSM use some can only be viewed and some only the network provider can access The Medi Link GPRS GSM unit connects up to the mob...

Page 5: ...nnels designed to efficiently communicate in a particular manner The most common of these is the Voice channel This channel assumes the communication is voice in nature and thus processes the signal by sampling slicing into packets and compressing before transmitting and on the other side uncompressing joining the packets back together and converting back to some sort of analogue voice signal This...

Page 6: ... the notched corner toward the socket shown in the diagram below then pushed in until it clicks into place When correctly inserted the edge of the SIM card will not extend into the battery compartment Upon a second push the SIM card will click out of the SIM socket ready for removal When the SIM card is correctly inserted sufficient room is available for the Battery Replace the Battery Care must b...

Page 7: ...di Link GPRS GSM Unit refer to Section 5 2 Supply Power to the Medi Link GPRS GSM Unit by Connecting the AC Plug Pack to a Power outlet and connect the Plug to POWER underside the Medi Link GPRS GSM Unit Sliding the Battery ON OFF Switch to the ON position underside the Medi Link GPRS GSM Unit 3 While in Program Mode enter the 4 digits Client Account Code Number Primary Phone Numbers for GSM If re...

Page 8: ... unit This will reset all Programming Options and will have to be completely reprogrammed again in the new mode If the code is unknown then the Medi Link unit will default to the previous Product Type and it s Option Programming will be maintained The Medi Link unit will remain in this Mode for only 5 minutes if the code hasn t been entered 1 Hold down the CANCEL Green and HELP Red Buttons and Pow...

Page 9: ...HELP Buttons at the same time The Medi Link unit will beep 3 times to acknowledge that the digit has been programmed Repeat this process until all digits are programmed Note programmed a as the first digit will delete the Client Account Numbers 3 Press the CANCEL Button to move to the next Program Option 9 3 Programming PHONE NUMBERS GSM If Required Option Descriptions Note up to 30 Digits Maximum...

Page 10: ...e to the next Program Option Svr 1 Port is displayed Press the HELP Button 1 Pressing the HELP Button again to step through the digits 1 2 3 4 5 6 7 8 9 and 0 To Store each digit press the CANCEL and HELP Buttons at the same time The Medi Link unit will beep 3 times to acknowledge that the digit has been programmed Repeat this process until all 4 digits are programmed in 2 Keep Pressing the CANCEL...

Page 11: ...ess the HELP Button The Medi Link unit displays the SIM Provider eg Telstra Mobile cannot be changed but are there for your reference only Press the CANCEL Button to move to the next Program Option SIM APN is displayed Press the HELP Button The Medi Link unit displays the SIM APN eg Telstra intern cannot be changed but are there for your reference only Press the CANCEL Button to move to the next P...

Page 12: ...ing Options has been Defaulted Press the CANCEL Button to move to the next Program Option 9 7 Programming REPORTS Option Descriptions Warning Do not adjust refer to SmartLink 13 REPORTS is displayed Press the HELP Button NB This Option is only available on the Medi Link 3G PSTN unit V1 7 100 827 Do not adjust refer to SmartLink Press the CANCEL Button until Mode is displayed Press the HELP Button ...

Page 13: ...ur is displayed Once the hour is set press the CANCEL Button to begin setting the minutes In a similar fashion press the HELP Button until the correct minutes are displayed 3 After the minutes have been set press the CANCEL Button to move onto setting the Year Month and Day 4 While in the Set Date menu press the HELP Button until the correct year is selected After the year has been set press the C...

Page 14: ...amming Lead Part No 450 185 For more information refer to the SmartLink Up Download Programmer Installation Manual a Using the Direct Programming Lead Part No 450 185 b External Modem Fax Defeat Ensure that the PSTN Land Line has the Caller ID Enabled The Medi Link unit will Call Back to established the Link for the UpDownload Programmer Medi Link CELLULAR Medi Link CELLULAR PSTN ...

Page 15: ...for service diagnostics See below NOTE If response was not received from the Server the Medi Link performs up to 10 reporting attempts rotating around the programmed Servers There is no delay between the attempts These states occur after the GPRS GSM module has made contact with the service provider s access point The GPRS GSM manages the access point connection internally The GPRS GSM module may ...

Page 16: ...for service diagnostics See below NOTE If response was not received from the Server the Medi Link performs up to 10 reporting attempts rotating around the programmed Servers There is no delay between the attempts These states occur after the GPRS GSM module has made contact with the service provider s access point The GPRS GSM manages the access point connection internally The GPRS GSM module may ...

Page 17: ... and if programmed to do so the Medi Link will start polling the receiving Server at 60 Minute intervals Default value programmable These polling reports are identical to any other Medi Link report but is unique in its contents so the receiving Server will reset it s time for the next expected report A division of NESS CORPORATION PTY LTD Copyright SmartLink November 2013 Unit 4 56 Norcal Rd Nunaw...

Reviews: