Smarteh LPC-2.DI5 User Manual Download Page 1

USER MANUAL

Longo programmable controller
LPC-2.DI5
Digital Input module

Version 6

SMARTEH d.o.o. / Poljubinj 114 / 5220 Tolmin / Slovenia / Tel.: +386(0) 388 44 00 / e-mail: [email protected] / www.smarteh.si

Summary of Contents for LPC-2.DI5

Page 1: ...USER MANUAL Longo programmable controller LPC 2 DI5 Digital Input module Version 6 SMARTEH d o o Poljubinj 114 5220 Tolmin Slovenia Tel 386 0 388 44 00 e mail info smarteh si www smarteh si...

Page 2: ...Longo programmable controller LPC 2 DI5 Written by SMARTEH d o o Copyright 2016 SMARTEH d o o User Manual Document Version 6 April 2016 i...

Page 3: ...ot include damage due to transport or because of unconsidered corresponding regulations of the country where the module is installed This device must be connected properly by the provided connection s...

Page 4: ...r LPC 2 DI5 Longo programmable controller LPC 2 DI5 1 DESCRIPTION 1 2 FEATURES 2 3 INSTALLATION 3 3 1 Connection scheme 3 3 2 Mounting instructions 5 3 3 Module labeling 6 3 4 Technical specifications...

Page 5: ...annels are available for input connection Module s inputs are galvanic isolated Module can be used in a wide range of operation LEDs indicate state of contact on correspondent input refer to the Table...

Page 6: ...able controller LPC 2 DI5 2 FEATURES Figure 1 LPC 2 DI5 module Table 1 Technical data Eight standard digital inputs galvanic isolated Flexible input for wide use of operation Standard DIN EN50022 35 r...

Page 7: ...V DC 24 V DC digital input IN2 4 U 2 24 V DC 10 mA output Power supply output IN3 5 I Digital input 0 24 V DC 24 V DC digital input IN3 6 U 2 24 V DC 10 mA output Power supply output 1 Wires connecte...

Page 8: ...8 15 I Digital input 0 24 V DC 24 V DC digital input IN8 16 U 3 24 V DC 10 mA output Power supply output Table 3 Digital input specification IN1 1 IN8 15 Off RSW 5 k On RSW 40 k Max input frequency 5...

Page 9: ...quired Mount each module to the DIN rail first then attach modules together through K1 and K2 connectors 4 Connect digital inputs wires according to the connection scheme in Figure 2 5 Switch ON main...

Page 10: ...4 year of code opening 001 derivation code 001 version code reserved for future HW and or SW firmware upgrades 3 D C 16 05 is the date code 16 week and 05 year of production Label 2 description 1 S N...

Page 11: ...nput threshold ON 5 k OFF 40 k Connection type screw type connector for stranded wire 0 75 to 2 5 mm2 Max transition time 1 s Dimensions L x W x H 90 x 53 x 60 mm Weight 100 g Ambient temperature 0 to...

Page 12: ...S The following table describes all the changes to the document Date V Description 13 04 16 6 General update 01 07 12 5 CGP General update 11 05 10 4 Updated warranty permanence 30 06 05 3 The initial...

Page 13: ...Longo programmable controller LPC 2 DI5 5 NOTES 9...