Pad Signal
Lost
Low Battery
Pad 2
Monitor Not
In Use
Pad 1
Pad Signal
Lost
Low Battery
Pad 2
Monitor Not
In Use
Pad 1
Reset
Quick Start Instructions
TL-2100G
Need Set-up Help? (800) 650-3637
AA Batter
y
+
-
Melody
3 2 1
Volume
Decrease/Increase
AA Batter
y
+
-
AA Batter
y
+
-
The CordLess® Monitor can work in two modes:
1. With one CordLess® bed or chair sensor pad
2. With two CordLess® bed sensor pads
Install Battery, Adjust Settings
1
Program Sensor Pad(s)
2
3
A. Test Pad 1
B. Test Pad 2
Program
Button
Pad 1
Pad 2
Reset
Low Battery
Status/
In Use
Check
Pad
Pad Signal
Lost
Low Battery
Pad 2
Monitor Not
In Use
Pad 1
Pad Signal
Lost
Low Battery
Pad 2
Monitor Not
In Use
Pad 1
Remove the protective boot.
Insert batteries as shown.
CordLess Monitor settings:
Volume, Melody
Close the battery door and
secure it with the small
Phillips-head screw.
Place the monitor in its
protective plastic boot.
Resetting the Monitor/Tamper Proof
™
Mode with Caregiver Key
™
(Optional)
Test the System for each Pad
Caregivers can choose to reset the
CordLess Monitor in either of two ways:
Option 2 allows only the caregiver to
reset the monitor.
For more information about
the Caregiver Key™ and how it can
be used in your facility’s Fall Risk
Assessment Program call
800-650-3637
IMPORTANT: When using the
TL-2100G CordLess® Monitor with two pads,
place all the components (the two pads and the monitor) within 15 feet of each
other. Test the system before each use.
When using “Reset Button ON” Mode
Press the Reset/Low Battery button to
reset the monitor.
When using “Reset Button OFF”
Place the Caregiver Key
™
over the red dot to
reset the monitor.
Alert Tone/Melody Adjustment
Default Setting: Melody 1
Alert Volume Dial
Default Setting: Full Volume
Reset
Button
Monitor ready to
program
Pad 1
Monitor ready to
program
Pad 2
Exit Programming
for single pad use
Program 2nd pad
Option 1
OR
Option 2
SMART CAREGIVER CORPORATION
Tel: 800-650-3637 | www.smartcaregivercorp.com
Reset
Low Battery
PR
OG
RA
M
TL
-2
00
GU
R2
Pad Signal
Lost
Low Battery
Pad 2
Monitor Not
In Use
Pad 1
Pad Signal
Lost
Low Battery
Pad 2
Monitor Not
In Use
Pad 1
Reset
Pad Signal
Lost
Low Battery
Pad 2
Monitor Not
In Use
Pad 1
(See separate instructions for CordLess® Floor Mat operation)
Place one or two CordLess bed or chair pads within reach. Each sensor
pad comes with a CordLess Transmitter connected and turned on.
Press and hold the Program Button on the back of the monitor until
you hear 3 short beeps to enter programming mode. Release the
button.
Press and hold the Program
Button until you hear 3 short
beeps to enter programing
mode.
Apply pressure to pad
Monitor will beep two times
Status light will blink while pressure remains on pad
When pressure is removed, monitor will alarm
Press reset button to silence alarm or use caregiver key depending on your setting.
See switch on side of monitor to select the
option of your choice.
“Reset Switch ON”:
Pressing the
Reset/Low Battery
button on the
front of the monitor.
“Reset Switch OFF”:
Placing the
optional Caregiver Key over the red
dot on the front of the monitor.
Reset
Reset
Reset
Reset
Reset
0.3A
Remark: Revised again by Edwin
Place pressure on first
pad for 3 seconds,
then release to
program as
Pad 1
.
Monitor beeps twice.
Place pressure on second pad for 3
seconds then release to program as
Pad 2
. Monitor beeps twice.
Press the
Reset
Button to
exit programming.
*NOTE: When there are 2 pads programmed to the monitor and
no one is on the pads, press the reset button twice to reset the
monitor.