Appendix D
Managing SMART
Board 6000S (C)
or 6000S series displays using RS-232
smarttech.com/kb/171414
88
Power state
Description
POWERSAVE
The screen is off, and the display is a very low power state. The display enters
READY or ON state when one of the following occurs:
l
A user presses the
Power
button
on the convenience panel or the remote
control.
l
You send the
set powerstate=ready
or
set powerstate=on
command.
This power state is the default energy saving mode for displays set to an EU
location.
Note
The EU uses “standby” to describe this power state.
UPDATEON
The display is updating firmware. Do not turn off the display.
UPDATEREADY
The display is updating firmware while the screen is off. Do not turn off the
display.
With the exception of
get powerstate
and
set powerstate
, commands are available only when the
display is in READY or ON power state.
Input commands
Get command
Set command
Response
If one display is connected
get input
set input[Value]
Where
[Value]
is one of the following:
l
=hdmi1
l
=hdmi2
l
=hdmi3
l
=vga1
l
=ops1
l
=usbc1
l
=android
Note
The usbc1 set command applies
only to displays equipped with
USB Type-C connectors.
input=[Value]
Where
[Value]
is one of the following:
l
hdmi1
l
hdmi2
l
hdmi3
l
vga1
l
ops1
l
usbc1
l
android
l
none