Appendix C
Managing the SMART Board 6000S (V3) display using RS-232
smarttech.com/kb/171414
81
Serial number commands
Get command
Response
get serialnum
serialnum=[Value]
Where
[Value]
is the serial number.
Part number commands
Get command
Response
get partnum
partnum=[Value]
Where
[Value]
is the part number, including the revision.
Model number commands
Get command
Response
get modelnum
modelnum=[Value]
Where
[Value]
is the model number of the display.
Resolving issues with managing the display using
RS-232
The following table presents common issues with managing the display using RS-232 and explains how
to resolve them:
Symptom
Troubleshooting steps
Managing the display using RS-232
isn’t working as expected.
l
Make sure all the cable connections are secure.
l
Restart the display and the remote management system.
Turning off, turning on, and resetting the display on page
45.
l
Configure the serial interface settings in your RS-232 terminal application.
Configuring the computer’s serial interface settings on page
You’re experiencing other issues
with managing the display using RS-
232, or the previous steps don’t
resolve the issue.
Chapter 5 Troubleshooting on page
51.