Operating Instructions
To turn the System On
To Adjust the Set (or desired) Temperature
To select the System Mode & Fan Speed.
To select the Fan Mode.
With each press of the “ON” button, the FMT will toggle between on and off mode. The FMT retains in memory the last temperature set point and
operational mode. These values are used when turned on.
When no buttons are pressed, the LCD indicates the current room temperature. When the
First press the “Select” button (the current mode will start to flash rapidly in the LCD) then by pressing the up (+) or down (-) buttons the FMT will
toggle between Heat, Cool, Heat & Cool (Auto season change over) or fan only modes. Once the desired mode is displayed in the LCD press the
select button again to select the desired fan speed. Select the desired speed using the up (+) or down (-) buttons. The available selections are Lo,
Med , High or Auto fan (indicated by all three fan speeds being on). Once the desired fan speed is set press the select botton again to select Auto or
manual fan modes, again press the
In heat only mode, the thermostat will only activate the system heating when the room temperature falls below the set (or
desired) temperature. Heat will be displayed in the LCD to indicate this mode is set. When the FMT is calling for the system to heat, the
word “HEAT” will flash slowly in the LCD.
In cool only mode the thermostat will only activate the system cooling when the room temperature raises above the set (or
desired) temperature. Cool will be displayed in the LCD.
In Auto mode the thermostat will automatically activate the system heating or cooling to maintain the
set (or desired) temperature to within 1 Deg C. For example, if the set temperature is 21 deg C, the FMT will activate the system cooling
when the room temperature raises to 22 deg C or activate the system heating if the room temperature falls to 20 deg. The LCD will
indicate Auto Season Mode by displaying both “Heat & Cool” in the LCD.
In continuous fan only mode the FMT will only run the system fan regardless of the set and room
temperature. The FMT will not call for system heating or cooling. Fan only mode should be used to improve building ventilation.
The FMT can control the system fan in a number of ways. In addition to the previously described Continuous Fan Only Mode (where the system fan
will run continuously without a call for system heating or cooling), the FMT can also control the System Fan to run only during a call for heating or
cooling, or to run continuously AND call for system heating and cooling when required. To select the appropriate Fan mode press the “Select” button
twice, (or until the words “Fan” or Auto Fan” are displayed in the lowest section of the LCD - These words will be flashing quickly). Pressing the
In Fan mode the system fan will run continuously, however the FMT will also control the room temperature as dictated by the Heating,
Cooling or Auto modes described above. The FMT will indicate that this mode is active by displaying the word “Fan” in the lowest section
of the LCD.
In Auto Fan mode the FMT will only turn on the system fan when there is a call for system heating or cooling.
up (+) or down (-) buttons is first pressed the LCD will
flash rapidly and change to indicate the Set (or desired) temperature. The word “SET” will also be displayed in the LCD to confirm the set
temperature is being adjusted.
When the desired temperature is shown and there are no further button presses the LCD will stop flashing and again indicate the current room
temperature. The new desired temperature is now active.
up (+) or down (-) buttons to set the desired mode. Press the select button once again to return to normal mode.
When the FMT is calling for the system to cool, the word “COOL” will flash slowly
in the LCD
When the FMT is calling for the system to heat or cool the
appropriate word will flash slowly in the LCD.
The FMT has the ability to control the system fan through 3 fixed fan speeds. Low, Medium and High Speed. Further in Auto
fan speed mode (indicated by all three modes being shown) the FMT will automatically increase or decrease the fan speed depending on
the differential between room temperature & set temperature.
up
(+) or down (-) buttons will toggle the FMT between “Fan” and “Auto Fan” mode. Once the desired mode is displayed in the LCD, stop pressing
buttons and after a few seconds the display will stop blinking and the new desired fan mode is set.
The LCD will indicate that
this mode is active by displaying the words “Auto Fan” in the lowest section of the LCD.
Heat Mode:
Cool Mode:
Auto Season Change over Mode:
Continuous Fan only Mode:
Auto Fan Mode
Fan Speed:
Fan Mode
Model FMT24-HC113S
24 Volt Single Stage HeatCool thermostat
with 3 Speed Fan
Auto Changeover - Non Programmable
Congratulations on the purchase of your new
Electronic Thermostat!
Your new Smart Temp thermostat has been built using the best components
and design philosophy. As a consequence of this, if properly installed your new
electronic programable thermostat will provide you with years of trouble free
and reliable service.
The Smart Temp FMT has been designed to be attractive, highly reliable and
simple to use. Please take the time to read these simple instruction to
familiarise yourself with the function and features offered in this product.
Smart Temp
Thermostats
TM