6
Main Display and Operational Modes
This manual refers to firmware version 1.5.6.3 and subsequent updates. Please update
SmartCAM Zen to the latest version available through its Burner software as specified in
chapter 9. The operating mode SmartCAM Zen is in when it is turned on is defined as
SLEEP MODE.
SmartCAM Zen powers up in what is called
SLEEP MODE.
In this mode, SmartCAM Zen keeps all the sensors and signal processing components
active without displaying any graphic elements(LED Bars and main display are OFF).
The main operating mode is called
STANDARD MODE
and it is the operating mode in
which the LED bars show the data coming from the sensors according to the user's
choices. The main display of SmartCAM Zen allows the direct visualization of the selected
axis with an accuracy of up to 0.1 °.
The other operating mode is the
SETUP MODE
. In this operating mode, the LED bars
continue to show data from the sensors based on the user's choices while the display
shows all possible menu items.