background image

USI Level 

 

User Manual 

Smart Storm Ltd. 

 

Page 1/20 

 

 
 

 

USI Level METER

 

INSTRUCTION MANUAL

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Date  : 23/01/2021 
Version: 2.3

The Old Mill 

Lower Slack 

Wainstalls 

Halifax, HX2 7TJ 

Tel: +44 (0)1422 363462  

E: 

[email protected]

 

Web: www.smartstormgroup.com 

Summary of Contents for USI

Page 1: ... Smart Storm Ltd Page 1 20 USI Level METER INSTRUCTION MANUAL Date 23 01 2021 Version 2 3 The Old Mill Lower Slack Wainstalls Halifax HX2 7TJ Tel 44 0 1422 363462 E Enquiries smartstormgroup com Web www smartstormgroup com ...

Page 2: ...ofile 6 2 1 4 Display Config 7 2 2 Setup 8 2 2 1 System 8 2 2 2 Device 9 2 2 3 Volume 10 2 2 4 Relay 11 2 2 5 Site Details 12 2 2 6 About 13 2 3 Logger 14 2 3 1 Download 14 2 3 2 Data Viewer 15 3 How To 16 3 1 Download 16 3 2 Calibrate Input 16 3 3 Define Device 16 3 4 Change the software 17 4 Wiring Diagram 18 5 Dimension 19 6 Glossary of Terms 20 ...

Page 3: ...gram V CHAPRONT Welcome to the USI The USI uses intuitive programming through its touch screen display The user will navigate through the different screen with ease to calibrate programme and display chosen options This largely negates the need for a detailed instruction manual and provided the user is familiar with the generic terms see glossary he or she should enjoy trouble free operation ...

Page 4: ...20 2 Design 2 1 Run 2 1 1 Text What Display the current readings value Description Displays the value of Flow Temperature Totaliser and all of the defined inputs The box below the value displays the daily readings of the last 7 days Scroll to view ...

Page 5: ... Manual Smart Storm Ltd Page 5 20 2 1 2 Graph What Shows the measured readings as a graph Description Show each readings as a graph The range of the graph is defined in Setup System see section 2 2 1 System on page 8 ...

Page 6: ...orm Ltd Page 6 20 2 1 3 Echo Profile What Show the actual signal received by the sensor Description The signal received by the sensor is display on the graph The distance calculated is shown by a green arrow at the top of the graph ...

Page 7: ...USI Level User Manual Smart Storm Ltd Page 7 20 2 1 4 Display Config What Shows the current configuration of the device ...

Page 8: ...to its factory settings Please download any data before doing that see section 3 1 Download on page 17 Log Interval Define the time between each logged value The USI will read value every seconds on that interval and logged the average at the end of the interval Communication Enable and configure the Ethernet capabilities The IP address and the password will be required to connect to the USI User ...

Page 9: ...d through the software to identify this tank Height Maximum height of the tank Sensor Type Blanking distance distance that is made invisible to the sensor Can be used to remove a fixed object for example a ladder from the reading of the sensor Offset Difference between the top of the tank and the bottom of the sensor Manual Temperature The temperature can be set to a fixed value by turning the man...

Page 10: ... in the box Shape Select the shape of the tank For each tank a drawing will be displayed to help entering its dimension Volume Max Maximum volume of liquid in the tank This volume is automatically calculated by the software when the dimension are changed Display Tonne Select whether to display the weight of the liquid in the tank If enabled the user will be asked to enter the specific gravity of t...

Page 11: ...ff point and pump Pump The pump option can enabled various behaviour for relays to work together Fixed Pump the relay work by itself Alternate pump The relay in this mode will start alternatively Duty Assist If the main relay is still on after a given amount of time the other relay will start Alternate Duty Same as duty but the main relay will be changed alternatively ...

Page 12: ...art Storm Ltd Page 12 20 2 2 5 Site Details What Details of the site in which the device is installed Description The Name and the ID are used to name the data file Please enter something meaningful to help recognise the file ...

Page 13: ...USI Level User Manual Smart Storm Ltd Page 13 20 2 2 6 About What Display version and copyright information Description Version The version of the software ...

Page 14: ...scription When pressing a download button the user will be asked to enter a Site Name if this has not been done before The site name is used as a default for the downloaded file Download If there is an existing file append the new data to the file otherwise create a file and ask whether to download everything or just a time range Choose Date Range Download data in the specified time range ...

Page 15: ...rence viewer can be used Daily A summary of a daily readings display as a report range 4 weeks Detailed Detailed readings display as a report range 1 day Graph Detailed readings display as a graph range 4 weeks The range is the maximum amount of data that can be displayed by the viewer That range can be picked at any point in the logged data ...

Page 16: ...Calibrate button corresponding to your Input 2 On the Calibrate Input window see section 2 2 5 Calibrate Input on page 12 for each button under New Value do the following 1 Press the button next to it will be displayed the value read by the 4 20mA using the previous calibration if the input has never been calibrated before the previous value will be measured using a default calibration setting 2 O...

Page 17: ... To select which application to run 1 Close the current application using the Terminate Button on the Setup page The password is 4279 This Terminate button is only visible when logged as an Engineer password 2010 2 Once the application is closed you will see the Windows Desktop Double tap My Device to open this folder 3 Double tap Nand Flash to open it 4 Double tap 0 Installer to run the installer...

Page 18: ...USI Level User Manual Smart Storm Ltd Page 18 20 4 Wiring Diagram ...

Page 19: ...USI Level User Manual Smart Storm Ltd Page 19 20 5 Dimension All dimensions are in millimetres ...

Page 20: ...ow span No Flow Distance The distance from the sensor to the surface when no flow is current Penstock a penstock is a mechanised gate that can be lowered into a flow channel to regulate flow volumes pH external a 4 20mA input signal from an external pH meter can be calibrated and logged by the USI pH internal the USI has an integrated pH meter which can be calibrated directly with a pH sensor Prim...