A P P E N D I X B
Remotely managing your system through an RS-232 serial interface
65
Command
Response
Powered off
set
emergencyalertmsg
[target]
emergencyalertmsg=
[current]
no
get
emergencyalertmsg
emergencyalertmsg=
[current]
no
set emergencyalert
[target]
emergencyalert=
[current]
no
get emergencyalert
emergencyalert=
[current]
no
get signaldetected
signaldetected=
[current]
yes
The response varies depending on the power
mode.
Field definitions
Field
Possible values
Description
target autosignal
l
= on
l
= off
The ranges must match the OSD settings.
current autosignal
l
on
l
off
The ranges must match the OSD settings.
target lampreminder
l
= on
l
= off
The ranges must match the OSD settings.
current lampreminder
l
on
l
off
The ranges must match the OSD settings.
target highbrightness
l
= on
l
= off
The ranges must match the OSD settings.
current highbrightness
l
on
l
off
The ranges must match the OSD settings.
target autopoweroff
l
+ val
l
– val
l
= 0 to 240
The ranges must match the OSD ranges.
current autopoweroff
l
+ val
l
– val
l
= 0 to 240
The ranges must match the OSD ranges.
target zoom
l
+ val
l
– val
l
= 0 to 30
The ranges must match the OSD ranges.