background image

P C I 3 0 2 O M M E

MAR / 03

Version

1.1 / 1.2 / 2.0

плата расширения для прямого подключения ПК к датчикам, 
измерительным преобразователями и другим устройствам с 
поддержкой Foundation Fieldbus www.esma-rt.ru

Summary of Contents for PCI302

Page 1: ...P C I 3 0 2 O M M E MAR 03 Version 1 1 1 2 2 0 Foundation Fieldbus www esma rt ru...

Page 2: ...web www esma rt ru www esma rt ru Specifications and information are subject to change without notice Up to date address information is available on our website smar...

Page 3: ...ommunications Controller 4 MAU0 3 Fieldbus Medium Attachment Unit 4 NVRAM Non Volatile Random Access Memory 4 Software Overview 5 HMI Human Machine Interface 5 PCI OLE Server 5 PCI302 Device Driver 5...

Page 4: ...11 Installation 11 Hardware Configuration 11 PCI302 V2 0 11 PCI302 V1 xx 11 Hardware Installation 12 PCI302 V2 0 12 PCI302 V1 xx 12 Software Installation 12 Updating the Firmware 13 APPENDIX E SRF SER...

Page 5: ...l PCs Featuring independent Fieldbus H1 31 25Kbps master ports and powered by a 32 bit RISC CPU Directly connected to the PC bus through PCI bus or ISA bus it provides a fast communication path betwee...

Page 6: ...ieldbus Link Master The PCI302 can manage each of its Fieldbus ports as a link master device Process Supervision Exploring advanced communication features of the Fieldbus protocol the PCI302 can be us...

Page 7: ...nnected Redundant operation 1 to 4 PCI302s on each Fieldbus distributed on different PCs Fieldbus configuration management and supervision Network access via Ethernet Client Server architecture via DC...

Page 8: ...e CPU to fast devices RAM NVRAM FLASH and DP Peripheral Bus 8 bit peripheral bus used by the CPU to connect to slow devices TIMERs and MODEMs Timer0 5 8 16 bit 3 channel universal timers used by the P...

Page 9: ...software levels which contains all structures required for data and command transfer between them CH0 63 PCI302 Fieldbus ports 0 63 The card independent ports running inside the PCI302 Each one includ...

Page 10: ...t NVRAM Data and configuration retention 2MB 32 bit NVRAM Data and configuration retention Fieldbus Interface PCI302 Number of ports 4 independents with DMA Physical Layer Standard ISA S50 02 1992 Bau...

Page 11: ...h W6 NVRAM BATTERY is factory set to the OFF position in order to avoid energy loss while the card is at Smar s stock or on the Customer s shelf BEFORE USING THE PCI302 V1 xx THE DIP6 SHOULD BE TURNED...

Page 12: ...Appendix B 8 Physical Dimensions PCI302 Version 1 1x Figure 5 PCI302 card V1 1x Physical dimensions mm PCI302 Version 1 2x Figure 6 PCI302 card V1 2x Physical dimensions mm...

Page 13: ...PCI302 Operation Maintenance Instructions Manual 9 PCI302 Version 2 0 Figure 7 PCI302 card V2 0 Physical dimensions mm...

Page 14: ...71 Cable Specification PIN Description 1 Signal 2 18 0DATA 0D 36 0DATA 0D 16 1DATA 1D 34 1DATA 1D 14 2DATA 2D 32 2DATA 2D 12 3DATA 3D 30 3DATA 3D NC GND shield GND Table 1 SC71 Pin Description Figure...

Page 15: ...pective serial number The PCI302 hardware is set through the dip switches located in the back of the card see figure 9 FY1PM105 CDR Figure 9 Dip Switches of PCI302 v1 xx card PCI302 DIP SWITCHES W1 W2...

Page 16: ...types of cards can be physically installed on the same computer but just one will work with the SYSTEM 302 PCI302 V1 xx After the hardware configuration turn on your PC again and check the functionali...

Page 17: ...2 firmware all fieldbus activities in the PCI302 will stop After the firmware download is done it will be necessary to download the PCI302 configuration via Syscon 1 Launch the FBTools Wizard located...

Page 18: ...rowse button to select the firmware file to be downloaded PCI abs file 5 After selecting the firmware file the Download button will be enabled Click on it to initiate the firmware download 6 A message...

Page 19: ...of the dialog box will show the progress of the operation 8 When the download is complete a dialog box will appear confirming that the program was downloaded successfully Click OK and wait a few minut...

Page 20: ...This characteristic is optional in PCI 2 1 specification but many of such systems provide 3 3 volts on all connectors In PCI 2 2 specification this 3 3 volts supply is a requirement Therefore PCI302v2...

Page 21: ...___________________________________ FAILURE DESCRIPTON Please describe the failure Can the error be reproduced Is it repetitive ________________________________________________________________________...

Page 22: ...PCI302 Operation Maintenance Instructions Manual E 2...

Page 23: ...operational limits temperature humidity etc according to the instructions manual In addition this Warranty Certificate excludes expenses with transportation freight insurance all of which are the cust...

Page 24: ...pair and SMAR and its dealer reserve themselves the right to refuse the service in cases not compliant to those conditions It is the customer s responsibility to tell SMAR and its dealer when the prod...

Reviews: