6 Mounting
SMA Solar Technology AG
Operating manual
SB55-LV-JP-41-BE-en-13
24
☐ Maintain the recommended clearances to walls as well as to other inverters or objects.
☐ If multiple products are mounted in areas with high ambient temperatures, increase the
clearances between the products and ensure sufficient fresh-air supply.
150
220
150
100
450450
310310
630630
450450
96
450450
100
310310
Figure 6: Recommended clearances(Dimensions in mm)
6.2
Mounting the product
Additionally required mounting material (not included in the scope of delivery):
☐ 3 screws, suitable for the support surface and the weight of the inverter (diameter: minimum
6 mm)
☐ 3 washers, suitable for the screws (outer diameter: minimum 18 mm)
☐ Where necessary, three screw anchors suitable for the support surface and the screws
CAUTION
Risk of injury due to weight of product
Injuries may result if the product is lifted incorrectly or dropped while being transported or
mounted.
• Transport and lift the product carefully. Take the weight of the product into account.
• Wear suitable personal protective equipment for all work on the product.