7 Technical data
7.1 PV generator connection data
7.2 Grid connection data
Max. input open circuit voltage
U
PV 0
400 V (based on -10 °C cell
temperature)
Input voltage, MPP range
U
PV
139 V ... 400 V
Max. input current
I
PV max
12.6 A
Max. input power
P
DC
1890 W
Recommended generator power
2050 Wp
All-pole isolator on the DC input side
DC plug connector
Overvoltage protection
Thermally monitored varistors
Voltage ripple
U
pp
< 10 % of the input voltage
Insulation protection
Ground fault monitoring (Riso > 1 M
Ω
)
Operating consumption
< 5 W (standby)
Reverse polarity protection
Short circuit diode
Nominal output power
P
ACnom
1550 W
Peak output power
P
ACmax
1700 W
Nominal output current
I
ACnom
6.7 A
Harmonic distortion of output current
(at K
U grid
< 2 %, P
AC
> 0.5 P
AC nom
)
K
IAC
< 4 %
Short-circuit strength
Grid-side via current regulation
Operating range, grid voltage
U
AC
198 ... 260 V AC
Operating range, grid frequency
f
AC
49.8 ... 50.2 Hz
All-pole isolation on grid side
Independent disconnection device
(MSD),
redundant design
Phase shift angle
(based on the current's
fundamental frequency)
cos Phi 1 (at nominal power)
Overvoltage category
III
Test voltage (50 Hz)
1.3 kV (1 s routine testing / 5 s type
testing)
Test surge voltage
4 kV (serial interface: 6 kV)
Internal consumption at night
0.1 W
Summary of Contents for SUNNY BOY 1700
Page 2: ......
Page 6: ...SMA Technologie AG Page 6 SB1700 11 SE2006 Installation Guide...
Page 8: ...Foreword SMA Technologie AG Page 8 SB1700 11 SE2006 Installation Guide...
Page 10: ...Safety information SMA Technologie AG Page 10 SB1700 11 SE2006 Installation Guide...
Page 38: ...Replacing the varistors SMA Technologie AG Page 38 SB1700 11 SE2006 Installation Guide...
Page 44: ...Contact SMA Technologie AG Page 44 SB1700 11 SE2006 Installation Guide...
Page 45: ......
Page 46: ......
Page 47: ......