Installation Manual
SMA SENSOR MODULE
MD.SEN-40 (PC-SENS.BG1)
MDSEN-40-IA-en-10 | Version 1.0
ENGLISH
Page 1: ...Installation Manual SMA SENSOR MODULE MD SEN 40 PC SENS BG1 MDSEN 40 IA en 10 Version 1 0 ENGLISH...
Page 2: ...icitly identified as such Missing designations do not mean that a product or brand is not a registered trademark Modbus is a registered trademark of Schneider Electric and is licensed by the Modbus Or...
Page 3: ...le 12 6 Connection 14 6 1 Safety during Electrical Connection 14 6 2 Cable Requirements 14 6 3 Preparing the Connection Cable 15 6 4 Preparing the Enclosure Opening on the Inverter 17 6 5 Connecting t...
Page 4: ...9 Contact 30 Table of Contents SMA Solar Technology AG Installation Manual MDSEN 40 IA en 10 4...
Page 5: ...trical devices and installations Knowledge of the applicable standards and directives Knowledge of and compliance with this document and all safety information 1 3 Symbols Symbol Explanation Indicates...
Page 6: ...Select Settings Enter 10 in the field Minutes Connects several elements to be selected Select Settings Date Button Key Button or key to be selected or pressed Select Next 1 5 Nomenclature Complete de...
Page 7: ...2053 319 The product must only be operated with energy meters with S0 interface in accordance with DIN EN 62053 31 IEC 62053 31 A list with SMA Sensor Module compatible products is available at www SM...
Page 8: ...doing so note that even if the DC load break is switched off there will be dangerous direct voltage present in the DC conductors of the inverter Damage to seals on the enclosure lids in subfreezing co...
Page 9: ...mponents included in the scope of delivery Position Quantity Designation A 1 SMA Sensor Module B 1 2 pole connecting terminal plate C 2 3 pole connecting terminal plate D 2 5 pole connecting terminal...
Page 10: ...anemometer or energy meter The SMA Sensor Module performs the following tasks Receive measured data from Pt100 or Pt1000 temperature sensors Receive measured data of an irradiation sensor that can ou...
Page 11: ...ly identifies the product The type label is located on the front of the product Figure 3 Design of the type label Position Explanation A Device type B Serial number C Hardware version You will require...
Page 12: ...y use a maximum of one SMA Sensor Module per inverter Procedure 1 Danger to life due to high voltages of the PV array When exposed to sunlight the PV array generates dangerous DC voltage which is pres...
Page 13: ...he upper edge and on the connection sockets at the same time until it audibly snaps into both side locking tabs of the communication assembly The connector strip on the back of the module is automatic...
Page 14: ...break is switched off there will be dangerous direct voltage present in the DC conductors of the inverter Damage to the inverter or product due to electrostatic discharge Touching electronic component...
Page 15: ...2 Shielding yes Conductor cross section 0 2 mm to 1 5 mm Maximum cable length 30 m Connection cable for S0 interface Number of conductors 2 Shielding yes Conductor cross section 0 2 mm to 1 5 mm Maxim...
Page 16: ...conductor 6 Attach each cable piece for shielding to a shield clamp To do so plug one end of each cable piece into the ring terminal lug of the shield clamp and crimp using a crimping tool 7 Strip off...
Page 17: ...on cables and store safely for later decommissioning 7 Lead the connection cable through the swivel nut and seal into the inverter 8 Screw the swivel nut of the cable gland on loosely 6 5 Connecting t...
Page 18: ...ature A1 GND Shield ground A2 I Current output A3 V Voltage input A4 V Voltage return A5 I Current return Cell temperature B1 GND Shield ground B2 I Current output B3 V Voltage input B4 V Voltage retu...
Page 19: ...ction of a temperature sensor with four conductor connection technology A2 B2 SMA Sensor Module A3 B3 A4 B4 A5 B5 A1 B1 Temperature sensor with Pt100 or Pt1000 measuring shunt Shield Figure 7 Connecti...
Page 20: ...g four conductor connection technology unlock the terminal positions 2 3 4 and 5 on the 5 pole connecting terminal plate using a suitable tool and plug the conductors of the connection cable into thes...
Page 21: ...e terminal block see Section 6 3 page 15 Pin assignment Figure 8 Pin assignment for terminal ANA IN Pin Signal Explanation B1 V Voltage input B2 I Current input B3 GND Reference potential of the suppl...
Page 22: ...n sensor with voltage output Procedure 1 Connect the connection cable to the irradiation sensor see the manual from manufacturer Trim the unneeded insulated conductors up to the cable shield and note...
Page 23: ...al of the supply voltage into this terminal position 6 Plug the first 3 pole connecting terminal plate into pin row A on terminal ANA IN 7 Plug the second 3 pole connecting terminal plate into pin row...
Page 24: ...r the connection of a remote terminal to the S0 interface Procedure 1 Connect the connection cable to the remote terminal and write down the conductor colors see the manual from manufacturer 2 Connect...
Page 25: ...2 1 3 Plug the 2 pole connecting terminal plate into pin the row on terminal S0 IN 4 If no further connections are required on the module or in the inverter close the inverter and commission it see t...
Page 26: ...anual When doing so note that even if the DC load break is switched off there will be dangerous direct voltage present in the DC conductors of the inverter 2 Remove all connecting terminal plates from...
Page 27: ...closure opening of the inverter with the corresponding sealing plug 7 Close the inverter and recommission it if necessary see inverter manual 7 2 Packing the Product for Shipment Pack the product for...
Page 28: ...ity 2 Measuring shunt Platinum sensor Pt100 platinum sensor Pt1000 Type of measurement Two conductor connection technology four conductor connection technology Measurement range 40 C to 85 C Typical m...
Page 29: ...ength 30 m Supply voltage for irradiation sensor Quantity 1 Output voltage 24 VDC Maximum power consumption 600 mW S0 interface Standard EN 62053 31 IEC 62053 31 Number of wires 2 conductor connection...
Page 30: ...49 561 9522 3199 Sunny Island Sunny Boy Stor age Sunny Backup Hydro Boy 49 561 9522 399 Sunny Central Sunny Central Storage 49 561 9522 299 SMA Online Service Center www SMA Service com Belgien Belgiq...
Page 31: ...6177 SMA Online Service Center www SMA Service com India SMA Solar India Pvt Ltd Mumbai 91 22 61713888 SMA Solar Thailand Co Ltd 66 2 670 6999 SMA Technology Korea Co Ltd 82 2 520 2666 South Africa S...
Page 32: ...www SMA Solar com...