Tools and supplies:
Required:
Measuring
tape, wire strippers, PLTC cable, wire nuts,
IDC connectors or butt splices, and cable ties.
Optional:
Dow Corning® 737 or equivalent
SloanLED approved neutral cure sealant.
NOTE:
3M™ Scotchlok™ connectors for
European installations only.
1.
Clean surface:
Clean inside channel letter
or mounting track (SloanLED recommends
minimum 0.32 in (8 mm) depth and 0.1875 in
(5 mm) width) with rubbing alcohol and allow
to dry.
2.
Peel and stick:
Using predetermined layout, remove tape backing and stick strip in place.
Ensure strip is firmly attached.
NOTE:
If installing in a narrow channel, tape may be unnecessary. Other means of securing strip
(sealant, vinyl, etc.) are also acceptable.
CAUTION:
Avoid pressing down directly on top of LEDs or circuit components and use caution
to not damage LEDs or circuit components in tight bends around sharp corners. The minimum
radial bend radius is 1 in (25 mm).
WARNING: Check Polarity: All
connections must be RED-TO-RED (+)
and BLACK-TO-BLACK (-). Reverse
polarity connections may damage the
LEDs and will void product warranty.
3.
Connections:
Sections may be connected
in series or parallel. The string of BendLUX
should not be connected to create a closed
circuit. Cap all unused, exposed wire ends.
NOTE:
To avoid significant line loss, do not
use more than 6 ft (1.83 m) in series.
Optional snapped/cut sections:
BendLUX can be snapped or cut into several sections to facilitate flat
bends and very tight radial bends. Sections may be cut or snapped on the black lines with “BREAK HERE”
markings. To snap, lightly pinch on either side of a break location as indicated by a hole, black line, and
“BREAK HERE” marking, using caution to not damage the adjacent LEDs and circuit components. Bend
approximately 90° once in each direction. To cut, move wires away from the cut line. Using a pair of scissors or
shears, carefully cut along the black line. Cut only the printed circuit board, being careful to not cut the wires.
Side
mounted
3M Scotchlok connectors for
European installations only.
Not UL recognized for
North American installations.
Note:
Modules must be mounted in an enclosed sign cabinet/box. This product is not suitable for
immersion or direct exposure to water for extended periods of time.
BendLUX
Installation Guide for 701960-6WS241