The information contained in this document is subject to change without notice.
SF-2100/SF-2150
SF-2200/SF-2250
Repair Parts and Maintenance Guide
1. Faucet delivers water in an uncontrolled manner.
A. Faucet is not working properly. Contact Sloan Technical Support.
2. Faucet DOES NOT deliver any water when sensor is activated.
INDICATOR: Solenoid valve produces an audible “CLICK.”
A. Water supply stop(s) closed. Open water supply stop(s).
B. Water strainer in control module is clogged. Close supply stops and
remove water inlet line at control module. Remove, clean and reinstall
strainer and water inlet line. Replace strainer if required.
INDICATOR: Solenoid valve DOES NOT produce an audible
“CLICK.”
A. Batteries low (battery powered models). Replace batteries.
B. Power failure (adapter powered models). Check power supply.
3. Faucet delivers only a slow flow or dribble when sensor is
activated.
A. Water supply stop(s) are partially closed. Completely open water
supply stop(s).
B. Water strainer in control module is clogged. Close supply stops and
remove water inlet line at control module. Remove, clean and reinstall
strainer and water inlet line. Replace strainer if required.
C. Aerator is clogged. Remove, clean, and reinstall aerator. Replace
aerator if required.
D. Faucet is not working properly. Contact Sloan Technical Support.
4. Faucet DOES NOT stop delivering water or continues to drip after
user is no longer detected.
A. Faucet is not working properly. Contact Sloan Technical Support.
5. The water temperature is too hot or too cold on a Faucet
connected to hot and cold supply lines.
A. Supply stops are not adjusted properly. Adjust supply stops.
DO NOT USE
abrasive or chemical cleaners (including chlorine bleach) to
clean faucet that may dull the luster and attack the chrome or special
decorative finishes. Use
ONLY
mild soap and water, then wipe dry with
clean cloth or towel. While cleaning the bathroom tile, protect the faucet
from any splattering of cleaner. Acids and cleaning fluids will discolor or
remove chrome plating.
When assistance is required, please contact
Sloan Technical Support at: 1-888-SLOAN-14 (1-888-756-2614).
TROUBLESHOOTING GUIDE
CARE AND CLEANING
203
Faucets and Soap Dispensers