1.  Faucet delivers water in an uncontrolled manner.

A.  Faucet is not working properly. Contact Sloan Technical Support.

2. Faucet DOES NOT deliver any water when sensor is activated.

INDICATOR: Solenoid valve produces an audible “CLICK.”

A. Water supply stop(s) closed. Open water supply stop(s).
B.  Water strainer in control module is clogged. Close supply stops and  

remove water inlet line at control module. Remove, clean and reinstall 

strainer and water inlet line. Replace strainer if required.

INDICATOR: Solenoid valve DOES NOT produce an audible 

“CLICK.”

A. Batteries low (battery powered models). Replace batteries.
B. Power failure (adapter powered models). Check power supply.

3.  Faucet delivers only a slow flow or dribble when sensor is 

activated.

A.  Water supply stop(s) are partially closed. Completely open water  

supply stop(s).

B.  Water strainer in control module is clogged. Close supply stops and 

remove water inlet line at control module. Remove, clean and reinstall 

strainer and water inlet line. Replace strainer if required.

C.  Aerator is clogged. Remove, clean, and reinstall aerator. Replace 

aerator if required.

D.  Faucet is not working properly. Contact Sloan Technical Support.

4.   Faucet  DOES NOT stop delivering water or continues to drip after 

user is no longer detected.

A.  Faucet is not working properly. Contact Sloan Technical Support.

5.  The water temperature is too hot or too cold on a Faucet 

connected to hot and cold supply lines.

A. Supply stops are not adjusted properly. Adjust supply stops.

DO NOT USE

 abrasive or chemical cleaners (including chlorine bleach) to 

clean faucet that may dull the luster and attack the chrome or special  

decorative finishes. Use 

ONLY

 mild soap and water, then wipe dry with 

clean cloth or towel. While cleaning the bathroom tile, protect the faucet 

from any splattering of cleaner. Acids and cleaning fluids will discolor or 

remove chrome plating.