Sling LSA
Section 7
Pilot Operating Handbook
Aircraft and Systems
Document Number: DC-POH-002-X-A-6
Page | 7-26
Revision: 3.0
Date: 2021/04/23
7.16
Lubrication System
This information is relevant for the 912 iS. For information regarding
the 912 ULS, please see the appendix at the back of this manual.
The engine is provided with a dry sump forced lubrication system with
a camshaft driven pump, with an integrated pressure regulator. The
pump delivers oil from the oil reservoir, through an oil cooler and oil
filter to points of lubrication.
Surplus oil emerging from the points of lubrication gather at the
bottom of the crankcase from where it is forced back to the oil
reservoir by piston blow-by gasses.
Oil temperature is sensed by a sensor located on the crankcase.
The lubrication circuit is vented at the oil reservoir. The oil reservoir is
mounted on the firewall.
The lubrication system has an approximate volume of 3.5 litres (3.7
Quarts/7.4 pints).