background image

Made in Norway

© Sleipner Motor AS  2018

SLEIPNER MOTOR AS

P.O. Box 519

N-1612  Fredrikstad

Norway

www.side-power.com

Keep this

manual onboard !

 8950/8955/8960/8965 

8940/8909C 

Control panel

SIDE-POWER

Thruster Systems

Installation and user’s manual

EN

Installasjon og brukermanual

NO

Installationsanleitung

DE

8940

8909C

8955

8965

8950

8960

Document id: 

3023

Revision:  

6

Summary of Contents for Side-Power 8909C

Page 1: ...orway www side power com K e e p t h i s m a n u a l o n b o a r d 8950 8955 8960 8965 8940 8909C Control panel SIDE POWER Thruster Systems Installation and user s manual EN Installasjon og brukermanual NO Installationsanleitung DE 8940 8909C 8955 8965 8950 8960 Document id 3023 Revision 6 ...

Page 2: ...en WICHTIG Das Panel funktioniert nur mit elektrischen Side Power Systemen mit integrierter elektronischer Kontrolleinheit und einem Kabelstrang mit 4 5 Leitungen und ist bei korrektem Einbau an der Vorderseite wasserdicht Trotzdem muß sichergestellt sein daß das Panel nicht unter Wasser kommt da dies zu einem Kurzschluß führen kann Hierdurch kann es zu einem unbeabsichtigten Start des Thrusters k...

Page 3: ...matic main switch if installed D Put the panel 1 in place and screw in and tighten the four screws 3 E Press gently each of the four corner clips 4 into their corner slot NB If the thruster runs the opposite way of the panel swap positions of the grey and the blue control cables in one contact either by the thruster or by the panel E Installasjon Finnengodposisjonforpanelethvordeterletttilgjengeli...

Page 4: ...ay of the panel swap positions of the grey and the blue control cables in one contact either by the thruster or by the panel EN Installation Installasjon Finn en god posisjon for panelet hvor det er lett tilgjengelig og ikke blok kerer andre kontroll enheter Bruk den medsendte malen til å merke av området og skjær ut det merkede området Dersom kantene rundt utskjæringen blir skadet ujevne på frems...

Page 5: ...tung noch Dichtmasse verwenden A Die Dichtung 2 in die dafür vorgesehene Vertiefung in der Rückseite des Panels einlegen 1 B Den Stecker des Panels mit dem vom Side Power kommenden Kontrollkabel verbinden C Falls ein automatischer Hauptschalter installiert ist optional diesen mit dem Stecker des Panels verbinden D Das Panel einsetzen 1 und die vier Schrauben eindrehen 3 E Die vier Eckstücke 4 vors...

Page 6: ...6 1278 xxM 5 LEAD CONTROL CABLE 6 1278 xxM 5 LEAD CONTROL CABLE 6 1277 xxM 4 LEAD CONTROL CABLE 6 1277 xxM 4 LEAD CONTROL CABLE STERN BOW STERN BOW STERN 6 1278 xxM 5 LEAD CONTROL CABLE Switch 5A fuse Switch 5A fuse Common negative 10A fuse IMPORTANT Common negatvie MUST be wired when using control panel 8940 and 8909C if separate battery banks are installed Bow and Stern thtrusters combined 6 127...

Page 7: ...Control Panel 8950 8955 8960 8965 8940 8909C version 3023 6 2018 7 General use Turn boat to port Turn boat to starboard To turn panel OFF To turn panel ON Bow Stern Thruster ...

Page 8: ...ave installed a single stern thruster because of space limitation in the bow In this case the stern thruster is used in the same way as a single bow thruster see above for moving the boat s stern How to use a bow and stern thruster combined The combination of a bow and stern thruster offers total manoeuvrability to the boat and the opportunity to move the bow and the stern separately from each oth...

Page 9: ...N Knöp fe einschalten Falls eine anderes Panel verwendet wird den On Off Schalter für die Bugschraube einschalten 4 Den Bug in die gewünschte Richtung bewegen rot Backbord Knopf für Richtung Backbord grün Steuerbord Knopf für Richtung Steuer bord Bei Verwendung eines Joystick Panels dieses in die gewünschte Richtung bewegen Kontrollpanels wie Fuß und Kippschalter können ebenfalls verwendet werden ...

Page 10: ...rtunities to do so Prior to refund of the purchase price Purchaser must submit a statement in writing from a professional boating equipment supplier that the installation instructions of the Installation and Operation Manual have been complied with and that the defect remains e warranty service shall be performed only by the Warrantor or an authorized Service Centre and any attempt to remedy the d...

Page 11: ...Control Panel 8950 8955 8960 8965 8940 8909C version 3023 6 2018 11 ...

Page 12: ...nt was correct at the time it was published However Sleipner Motor AS can not accept liability for any inaccuracies or omissions it may contain Continuous product improvement may change the product specifications without notice Therefore Sleipner Motor AS can not accept liability for any pos sible differences between product and document ...

Reviews: