CAUTION
To avoid possible damage to the meter or to the equipment under
test, follow these guidelines:
•
Disconnect circuit power and discharge all high-voltage
capacitors before testing resistance, continuity, diodes, or
capacitance.
•
Use the proper terminals, function, and range for your
measurements.
•
Before measuring current, check the meter’s fuses and turn
power OFF to the circuit before connecting the meter to the
circuit.
•
Remove test leads from the Meter before opening the Meter
case.
MAINTENANCE
•
Before opening the case, always disconnect the test leads
from all live circuits.
•
For continue protection against fire, replace fuse only with
the specified voltage and current ratings: F 250mA/250V
(Fast Blown) ø5 x 20.
•
Periodically wipe the case with a damp cloth and mild
detergent. Do not use abrasives or solvents.
GENERAL SPECIFICATIONS
Display: 3 1/2 digits LCD, Max. reading 1999
Over range indicate: Symbol “1” appear on the LCD
Zero adjustment: Automatic
Low battery indication: Symbol “
” appears on the LCD
Power: 12V battery
Dimension: 100mm(L) x 50mm(W) x 20mm(D)
Weight: 60g (including battery)
TECHNICAL SPECIFICATIONS
Accuracy is specified for a period of one year after calibration and
at 18ºC~28ºC(64ºF~82ºF) with relative humidity up to 75%.
Accuracy specifications take the form of:
±([% of R[Number of Least Significant Digits])