CONNECTION DIAGRAM
Thank you for your choice of the SKYRC e450, 100-240V AC balance charger. This unit is simple to use
but its operation does require some knowledge on the part of the user. Please read this entire operating
manual completely and attentively before using this product, as it covers a wide range of information on
operating and safety.
SKYRC e450 Charger is an economic, high quality 100-240V AC balance charger, designed for charging
LiPo, LiFe and LiHV batteries from 2-4 cells in balance mode. It can charge 6-8S NiMH batteries also.
The circuit power is 50W and max charge current can reach to 4A. There are four kinds of charge current
1A/2A/3A/4A that can be selected. You could select the proper charge current according to battery
capacity.
INTRODUCTION
OPERATION
SKYRC e450 comes with the built in power supply. You can connect the AC power cord to the AC socket
(100-240V AC) directly.
Insert the AC power cord into the charger.
Insert the AC cord into a wall socket (100-
240V). All LEDS will light for 1 second and the
battery type LED will flash green and red which
indicates the charger is ready to charge.
Select the battery type LiPo/LiFe/LiHV/NiMH
by press “BATT TYPE” button.
Select the proper charging current 1A/2A/3A/4A by the slide switch.
Connect the battery main charge lead to battery socket which is in the front side of the charger and
battery balance wire to balance port which is in the right side of the charger.
The charger starts charging. The charge status LED will glow to indicate charging is in progress.
When the battery is fully charged, the charge status LED will glow constant green. Unplug the battery
from the charger and the charge status LED will flash green which indicates the charger is ready to
charge another battery.
Please refer to following steps to charge the battery,
1)
2)
3)
4)
5)
-
1
-
-
2
-
INSTRUCTION
MANUAL
SK-100122
Multi Chemistry Charger
450
Charging LiPo/LiFe/LiHV Battery
The charge current varies from 1A(1000mA) to
4A(4000mA). The recommended charge rate is 1C
(battery capacity = charge current). 1C means:
capacity value = charge current.
Example:
LiPo cell of 2200mAh Capacity; 1C=2200mA
(=2.2A) charge current. You can choose 2A
current to charge the battery.
LiPo cell of 2800mAh Capacity; 1C=2800mA
(=2.8A) charge current. You can choose 3A
current to charge the battery.
LED green and red blinking
LED glows constant red
LED blinking red
LED blinking yellow
LED blinking green
LED glows constant green
The charger is ready to charge.
Battery capacity is less than 25% charged.
Battery capacity is between 25% to 50% charged.
Battery capacity is between 50% to 75% charged.
Battery capacity is between 75% to 99% charged.
Battery is fully charged.
EXPLANATION OF LED STATUS
This diagram shows the correct
way to connect your battery to the
e450 charger while charging in
balance mode. Failure to connect
as shown in this diagram will
damage this charger.
CAUTION:
6)
Charging NiMH Battery
Connect the battery main charge lead to battery socket which is in the front side of the charger.
Press and hold “BATT TYPE” button for 2 seconds to start charging. The charge status LED will glow
to indicate charging is in progress.
Always make sure you are charging NiMH battery under NiMH mode. Charging
Lithium
Battery
under NiMH mode can lead fire, personal injury or property damage.
WARNING:
When the battery is fully charged, the charge status LED will glow constant green. Unplug the battery
from the charger and the charge status LED will flash green which indicates the charger is ready to
charge another battery.
TROUBLESHOOTING
SPECIFICATION
AC Input
Battery Type
Cell Count
Charge Current
Cell Terminate Voltage
Circuit Power
Current Drain for Balancing
Dimension
Weight
100-240V
LiPo/LiFe/LiHV/NiMH
LiPo/LiFe/LiHV: 2-4S
NiMH: 6-8S
1A/2A/3A/4A ± 10%
LiPo: 4.2V ± 0.02V / LiFe: 3.6V ± 0.02V
LiHV: 4.35V ± 0.02V / NiMH: -
△
V
50W
300mA
69.4x110.7x40.5mm
220g
If there is an error, all four status LED of the charge will blinking
.
Once the error condition has been resolved, press “BATT TYPE" button to reset the charger.
If
the
error
can
not
be
solved, please disconnect the power cord from the wall socket and unplug the
battery from the
charger.
1
2
3
4
Dead cell or imbalance
between cells is too high
Connection break or
wrong connection
Over current protection
Polarity (+ and –) connections
of battery are incorrect
LED Blinking Times
Problem
AC 100-240V
Power
Jack
NiMH Battery
LED Indicator
LiHV Battery
LED Indicator
2S Balance Port
Battery
Socket
Battery Type Button
Charge Current Switch
LiPo Battery LED Indicator
LiFe Battery LED Indicator
LiPo
TO 100-240V AC
Socket
-
3
-
3S Balance Port
4S Balance Port
Select Battery Type
Select Charging Current
Solution
Check the connection between the charger
and
the battery.
Make sure the charge lead is connected
properly
to
the charger
and
ensure it is wired
correctly.
Safely dispose of damaged battery
Decrease charge rate to safe level for the battery
pack, or dispose of shorted battery