10
PICTURE 03
3. Operation
3.1 Starting
To switch ON the equipment follow the below instructions:
1 - Make sure the Disc Chamber # 01 (Pic.04) is closed and duly locked .
2 - Place the ON/OFF Switch# 02 (Pic. 04) on OFF position “O” .
3 - Make sure the Stumper # 03 (Pic;04) is on the Throat # 04 (Pic. 04)
4 - Make sure the Emergency Button # 05 (Pic. 04) is not activated.
5 - Push and release the Reset Button # 06 (Pic. 04)
6 - Press ON/OFF Switch # 02 (Pic.04) to position “I” to switch ON the processor.
3.1.1 Safety Systems
The Processor has two more safety systems:
A - the first one do not let the processor to start with an open Disc Chamber # 01 (Pic.04)
07
05
08
06
02
04
01
03
2.2.1 Procedure to Assemble the Discs
1 - Fit the Expeller Dish # 01 (Pic. 03) on the shaft # 03 (Pic. 03)
2 - Choose the Disc # 02 (Pic. 03) and fit the Disc on the shaft # 03 (Pic. 03)
3 - Tight the nut # 04 (Pic. 03) on shaft # 03 (Pic,03)
4 - Fit the Disc Chamber # 05 (Pic. 03)
5 - Tight the Chamber Locking Handles # 06 (Pic. 03)
6 - Align the Stumper # 07 (Pic. 03) with the throat # 08 (Pic03).