SkylinkHome WE-001 Quick Start Manual Download Page 1

2. SETUP

 

    respectively to the existing wires from the wall : 

Secure the Wall Switch with the provided screws.

  The two blue LEDs will be on.

    Note:  If the 2 blue LEDs remain off, please check and ensure the light 
    bulb is installed and in good condition.

status of the load connected

Setup of the Wall Switch is simple. Simply replace your existing wall switch 
by the Wall Switch. 

CAUTION
Installation is required and enclosed instructions must be followed 
carefully to all steps and notes. If you are uncertain or uncomfortable 
performing this installation, please consult a qualified electrician.  
This manual should also be retained for future reference. 

1. Turn off power to the circuit that you plan on installing the Wall Switch 
    to at the circuit breaker. 

WARNING
Failure to turn off power at the circuit breaker can result in electrical 
shock causing severe or fatal injury.

Note: 
The Wall Switch is designed to operate maximum load of 1000W at 
120VAC.  

2. Follow the diagrams below to install the Wall Switch with the 2 wires: 
    Live, Load.  Use the provided  wire nuts to connect these wires 

3. After all the wires are connected, ensure that all of the wire connectors 
    are attached securely and there should be no exposed copper wiring. 
    

4. Turn the circuit breaker back on. 

5. The 

 will be off. The Wall Switch is now 

    installed and you can begin programming to learn transmitters into the 
    Wall Switch. 

Load (red) to load and 

    Live (Black) to live. Ground (Green) to Ground.

3. PROGRAMMING TRANSMITTERS SENSORS

There are 2 operating modes with the 

 :

1) On/Off Mode - When a valid signal is received, it  will turn on or off the
    load

2) Countdown Timer Mode - When a valid signal is received, the load will  
    be on for a specific period of time,  1 minute, 5 minutes, 15 minutes, 
    30 minutes, or 60 minutes. This is mainly for  energy saving.

Wall Switch

In order to operate the 

remotely with a transmitter or sensor, it 

must be programmed to the 

.  Each module can be operated 

by up to 8 different transmitters (or 8  different command signals). 

Wall Switch 

Wall Switch

You can program multiple transmitters / sensors to the module and 
different transmitter / sensor can activate a different mode.

Push the switch 

    button on the Wall Switch. 

To program a transmitter into the Wall Switch,  follow the instructions 
below: 

Before you program a transmitter to the Wall Switch, decide the operating 
mode for this transmitter (On/Off Mode, or Countdown Timer Mode). 

1. Wall Switch must be installed and powered properly. 

The connected load should be on, and the 

    2 blue LEDs are off.

2. Press and hold the "SET" button for about 3 seconds, the  upper blue 
    LED flashes quickly, meaning it is in On/Off Mode programming sequence. 
    Release the "SET" button if you are programming  a transmitter to operate 
    in On/Off Mode.

3. If you are programming a transmitter to operate in Countdown Timer 
    Mode, continue to hold the "SET" button for about  10 seconds, until the 
    upper blue LED is on steadily on, then release  the "SET" button.

4. Transmit a "Learn" code from the transmitter. Refer to the manual of the 
    transmitter to transmit this "Learn" code. 

5. Once the transmitter is programmed, the both blue LEDs flash quickly  
    then stops flashing. You have successfully programmed the transmitter. 

Operating Mode

On / Off 

Countdown Timer

Upper LED Indication

Flashes quickly

Steadily On

Note: You must complete the programming sequence within the 
15-second interval, otherwise, the Wall Switch will quit from programming 
mode and you need to start again from step 1 if the blue LED is off. 

1. INTRODUCTION

Wall Switch
WE-001 

Model WE-001

Wall Switch

Wire nuts

TM

Thank you for your purchase of a SkylinkHome  receiver, Wall Switch, 
Model WE-001.  Simply replace your existing wall switch with this Wall 
Switch, you can then wirelessly turn on and off 

TM

 with a SkylinkHome   transmitter. 

The Wall Switch WE-001 can communicate with up to 8 transmitters, so 
user has the option to add more transmitters to the system, such as more 
remote controls, or motion sensors etc. 

All wireless signal communications within the 

  System are 

based on rolling code technology to ensure highest security is used. 

The following items are included in this package:

- Wall Switch
- Wire nuts
-  

lights or appliances, 

etc

 

TM

SkylinkHome

User’s Instructions

Red

Load

Green

Ground (Usually copper 

or green)

Grey Antenna

Do not cut the antenna!

Black

Live

SET 
Button

Switch  Button

Blue 
LEDs

4. SET TIMER DURATION

This section is for transmitters that are programmed for Countdown Timer  
Mode.

The timer for Countdown Timer Mode can be set to the following duration, 
meaning the light will stay on for the following time: 1 minute, 5 minutes, 
15 minutes, 30 minutes, or 60 minutes. Only one timer interval can be set.  
To set the timer duration, follow the instructions below.

Note:
Antenna 

( grey wire)

 -- Do not cut it, keep it as straight as possible. 

Put the antenna directly  into the dry wall or through a hole of the 
metal box into the dry wall to get more control distance with a remote. 

1. Wall Switch must be installed and powered properly. The connected 
    load should be off, and the 2 blue LEDs are on. The load must be off in 
    order to set the timer duration.

2. Press and hold the SET button for 3 seconds, the lower blue LED 
    flashes once. The number of flashes indicates the timer duration:

Number of Flashes

1

2

3

4

5

Timer Duration

1 min.

5 min.

15 min.

30 min.

60 min.

3. Continue to hold the SET button until it reaches the desired setting. The 
    status will change every 6 seconds, i.e. hold the SET button for another 
    6 seconds, you will see the number of flashes changes from  1 to 2, 2 to 
    3, etc. 

http://waterheatertimer.org/Remote-controls-for-home.html