SkyLink TS-101A Manual Download Page 1

Temperature  Sensor

1. INTRODUCTION

Model TS-101A

The Temperature Sensor is designed to monitor the temperature of a
specific area, whether that is the indoor temperature or outdoor
temperature. It works in conjunction with the AAA+

TM

 Control Panel, as

well as other Skylink’s alarm system such as SC-001 or AD-433S etc.
When the actual temperature exceeds the preset limit, the control panel
will either alert you or alarm will be triggered.

In this package, you should find the temperature sensor, 2 lithium batteries,
an external measuring probe for measuring outdoor temperature and
mounting  accessories.

Please follow the instructions below to set up the temperature sensor.

2 pcs
3.5 x 20 screws

Temperature
Sensor
(Batteries inside)

2. PROGRAMMING

There are several things you need to program:
1) Clock
2) Upper temperature limit
3) Lower temperature limit
4) Set the temperature unit (Fahrenheit / Celsius)
5) Compatibility jumper (J2)

Clock

The current time will be displayed when the “HOUR” or “MIN” button is
pressed.
To set the hour:
1. Press and hold the “HOUR” button.
2. While holding on to the “HOUR” button, press “UP” or “DOWN” to

select the hour.

3. Release all buttons after setting the hour.
To set the minute:
1. Press and hold the “MIN” button.
2. While holding on to the “MIN” button, press “UP” or “DOWN” to

select the minute.

3. Release all buttons after setting the minute.

Upper  Temperature  Limit

When the actual temperature is above the upper temperature limit, the
temperature sensor will send a signal to the control panel.
To set the upper temperature limit:
1. Press and hold the “HI” button.
2. While holding on to the “HI” button, press “UP” or “DOWN” to select

the upper temperature limit.

3. Release all buttons after setting the upper temperature limit.

Lower  Temperature  Limit

When the actual temperature is below the lower temperature limit, the
temperature sensor will send a signal to the control panel.
To set the lower temperature limit:
1. Press and hold the “LO” button.
2. While holding on to the “LO” button, press “UP” or “DOWN” to select

the lower temperature limit.

3. Release all buttons after setting the lower temperature limit.

Set  the  temperature  unit  (Fahrenheit  /  Celsius)

The temperature sensor can operate and
display temperature in Fahrenheit or
Celsius. To select the desire unit, open
the back cover you will see a jumper
connector  for  “C/F”  as  shown  below.
To select Fahrenheit, place a jumper on
this “C/F” connector. To select Celsius,
remove the jumper from this connector.

Note:  The  temperature  sensor  can  monitor  the  temperature  within  this
range: 157°F (69°C) to -3°F(-19°C).

External
measuring
probe

External
dry contact cable

You have now programmed the temperature sensor and you can
mount the sensor to the desired location.

2. PROGRAMMING (CONT)

Compatibility  Jumper

Refer  to  the  following  table  to  setup  the  sensor  to  work  with  different
Skylink’s Security System or Emergency Dialer. To select, open the back
cover you will see a jumper connector for “J2” as shown below. Use a
paper clip to remove the jumper connector.

AM-001, ML-001

Keep the connector in
default post

Reposition
connector to 2 posts

Models

Jumper J2 setting

SC-001, AA-433,
AD-433S, MS-2001,
ED-100

3. LEARN SENSOR TO AAA+

TM

 CONTROL PANEL

In order for the sensor to communicate with the control panel properly,
the sensor must be programmed to the control panel.  Follow the brief
instructions below or refer to the detail instructions from the AAA+

TM

User’s Instructions to program the sensor to the control panel.  Before
proceeding, please remove the battery isolator from the sensor.

4

[PROG]
[MPIN]

Enter Program-
ming mode

Enter master
password to
programming
mode

3 beeps for valid
password. 1 long
beep for invalid
password.

[3]

Select learn
sensor
programming

[0]  to  [9]

After  you  have
selected the zone,
that zone LED will
be on.

Activate  sensor

After [3] is entered,
some zone LEDs will
flash once, or twice,
some will be off.  The
zone LEDs represent
whether that zone is
already occupied  by
another sensor.
**See Table A below.

Select sensor
location

Refer to the dia-
gram below to
select the sensor
location, which
includes the zone
and sensor
number.

Once the sensor
is activated, the
signal will be trans-
mitted to the Con-
trol Panel which
will be stored.

You will hear [

Zone X

Sensor Y Accepted

],

where X and Y are
the zone and sensor
numbers you have
selected.

Activate  the
sensor  by
pressing the
red “Panic”
button on the
temperature
sensor.

Step

Keys

Function

Description

Note

1

2

3

Zone 1

SENSOR 1

Button  [1]

SENSOR 2

Zone 2

Zone 3
Zone 4

Zone 5

Button  [2]

Button  [3]

Button  [4]

Button  [5]

Button  [6]

Button  [7]

Button  [8]

Button  [9]

Button  [0]

This row :
Buttons for
Sensor 1
Zone LED :
Flash once

This row :
Buttons for
Sensor 2
Zone LED :
Flash twice

Note:
Each location is allowed to learn one
sensor only. Learning a sensor to a
location will clear the memory of the
sensor  previously  learnt.

Remove
back cover

Celsius

Fahrenheit

Reviews: