Summary of Contents for AT588

Page 1: ......

Page 2: ...wait at least 15 minutes after eating or drinking Do not turn off vehicle during retest Wait until test result is displayed before turning off vehicle The vehicle will be locked out permanently if service warning days expires If using below 40 F device needs to wait for 60 second countdown before taking a test Do not disconnect the handheld device at any time Do not open the device and break the t...

Page 3: ...unds until driver stops car turns Ignition Off Retest while driving refusal or driver inability to submit a sample allowed 6 mins to test FAIL Violation Alarm sounds until driver stops car turns Ignition Off Retest while driving refusal turn off car at this stage FAIL Violation Need to provide a new breath test Disconnection of Handset While Engine Running NOT Permitted Recorded on data logger Sta...

Page 4: ...arts Operation Gently insert the mouthpiece into the blowing tube Turn the key of vehicle to ON position To power on press and hold the TEST button until power on then release once device is on Wait for countdown 08 05 04 and 03 to 00 ...

Page 5: ...Description Remarks Blowing incorrect or no blow Blowing flow incorrect Blowing pressure incorrect Blowing interrupted Do not blow before beep is heard do not wait too long to blow into device after audible beep Blowing with breath temperature incorrect With the device off blow into the device several times to warm up then try again Suck incorrect or no suck after initial blowing Suck interrupt to...

Page 6: ...the vehicle can be started Blocking state Red solid light or red flashing light the breath alcohol concentration above limit value the vehicle can t be started and the device temporarily locks out vehicle Wait until the red light turns off to retest If retest fails again the duration of lock out time will be extended Button description Test Press this button to start the operation of test Test the...

Page 7: ...ecific instructions Random Retest Breath test after the vehicle motor has been started The green and red lights of handheld device will flash together and beep indicating test required The driver must carry out this test within 6 minutes The device will beep every 60 seconds to remind driver to take the test Driver must pull over to a safe location to take random retest Free restart When engine st...

Page 8: ...or 2 seconds short Beep 1 time short Beep 1 time short Beep 1 time long Beep for 2 seconds 3 days to lockout long Beep for 2 seconds short Beep 3 times short Beep 3 times short Beep 3 times long Beep for 2 seconds Violation record Breath alcohol concentration above the set limit at initial test Refusal rolling retest Breath alcohol concentration above the limit at retest Unplug handheld tester Ove...

Page 9: ...g humidity incorrect Do not eat or drink anything for at least 15 minutes before taking test Operation Temperature out of range environmental temperature is out of range No display On Handset Press and hold the TEST button until handset powers on Check the power of vehicle Turn on the key of vehicle Auto Off Finish the test process Handset posers off after error indication Low battery Low battery ...

Page 10: ...tion temperature 40 F 185 F Calibration check interval 60 days Control Box Operating temperature 40 F 185 F The humidity of environment for use 20 95 Working power DC12V Standby power Less than 20mA Free restart without test after turning off engine 3 minutes Temporary lock out for 5 minutes or longer time in accordance with local policy Period of test time for Retest 6 minutes Service Interval wi...