4O3A Signature – Antenna Genius User Manual
Page
46
of
55
The OM module is connected to AG#2. Configure OM module to use Port1A signal outputs
+12VDC, which will be used for 8xAB switch. Open AG Configuration Settings and check “2xAG
with OM control”. Click on Save and Reboot.
More details about OM Module configuration in chapter 11.2.
When we want to use particular antenna on AG#2, simply choose antenna input on AG#2
(manually, band data) and the OM module will switch the desired antenna on AG#2. Note that
antenna switching will occur without any condition or interlock. AG#1 will lose that antenna
momently.
GENIUS WARNING!
Coordinate your activity. You can switch-off antenna from AG#1 even if
that antenna is in use!
11.5.
Stacking multiple AGs into a superswitch by AB switches
You can now combine multiple 8x2 v2 Plus units for 16x2, 24x2, and even 32x2 switching
capability.
Implemented with a
Master
/
Slave
design. Once you configure the system you will be
connecting to the Master unit. It will be in charge for the overall logic of the system.
In the simplest scenario configuration, we use two AG 8x2 v2 Plus units and two 4O3A AB
Switches to create 16x2 switch.