Alarm Operation
1. When in the resistance measurement mode, press the AL button,
the AL symbol and the value of the alarm threshold will be displayed.
2. You can press the AL button several times to select one of
three alarm modes:
Low Alarm Mode:
When the measurement is below the alarm threshold,
a continuous beep will sound at low frequency. The
AL
symbol will show
on the display.
High Alarm Mode
: When the measurement is above the alarm
threshold, a continuous beep will sound at high frequency. The
AL
symbol will show on the display.
No Alarm Mode
: No measurement has been set in the alarm threshold.
3. Set the alarm threshold. The default setting is high alarm threshold of
20Ω. In the resistance measurement mode, press the POWER + AL
buttons to set the alarm threshold value. The AL symbol and the value
of the alarm threshold will be displayed. Press the A or Ω buttons
to increase or decrease the alarm threshold value, can range from 1 to
100Ω inclusively. You can now select one of the three alarm modes by
pressing the AL button several times. Once done, press the
to exit
the alarm value setting mode. This value will not change when the meter
is turned off.
Memory
Clearing the memory
Press the HOLD + MEM buttons for 3 seconds, the CLR symbol will
then appear on the display. Once the beep sounds, the memory has
been cleared. The meter will return to the measurement
mode automatically.
Saving measured values
Press the MEM button for 2 seconds, the MEM symbol will then appear
on the display. The number of records will automatically increase by
one, which is then indicated on the display. When the record is the 99th
or when the battery life is at less than 20%, a beep will sound when the
MEM button is pressed to indicate that the meter will not record the value.