![sks 300097 Installation Instructions Manual Download Page 3](http://html.mh-extra.com/html/sks/300097/300097_installation-instructions-manual_1289434003.webp)
SKS-Kinkel Elektronik GmbH
EN
300097 Basic additional speaker
Support-Hotline: +49 (0) 2661-98088-112
- 3 -
Version: 1.0
E-Mail: [email protected]
Document art. no. 97010500
1
Installation
Electrical shock hazard to persons. Danger of burns, damage to device and malfunctions. Observe VDE 0100
and VDE 0800 guidelines during installation. (Germany)
Counter measures:
Before beginning any work, deactivate and disconnect all energized electrical wires.
Secure the switched off/ disconnected lines against erroneous reconnection.
Use a measuring device to make sure that the wires are de energized.
Cover up any adjacent, energized or conducting components.
All work and all electrical connections must comply with the national provisions for the country in question and
must be performed by appropriately trained personnel.
DIN VDE 0100 must be observed and complied with in devices with a 230V connection.
2
Terminal designation
Terminal
Designation
1
Positive pole speaker via diode
4
Positive pole speaker
-
Positive pole speaker
3
Description
The additional speaker is connected to a previously existing indoor station. It may be able to the following SKS
indoor station series: HT4500, HT4600, HTV4600, HT925, HT926, HT7105 und HT3500.
Whether the indoor station is caller from the front door or the floor door there will be the ringtone at the additional
speaker.
4
Technical data
Electric data
impedance speaker
45 Ω
General
Ambient Temperature
-10°C to +45°C
Humidity
20% to 90% not condensing
Housing
Plastichousing
Dimensions (width x height x depth)
80 x 150 x 13 mm
Type
IP20