DOL 534 • DOL 539
18
Circuit Diagrams and Cable Plans
3.4 Setup of modules
Carry out setup of main module and selection of I/O modules
according to the requirements of the house controller in the
Technical | Installation | Run installation
or
Manual in-
stallation
menu.
The terminals B2-A, B2-B, B15-A and B15-B can be set up to
either 0-10V input or output depending on how many are re-
quired of each type.
Please note that if the setup of the main module is changed af-
ter the components have been selected, the controller may
move around on the connections.
B2-A
B2-B
B15-A
B15-B
11 in/2 out
Input
Input
Input
Input
9 in/4 out
Input
Output
Input
Output
7 in/6 out
Output
Output
Output
Output
3.5 Positioning of jumper
The jumper is only present on I/O module type 3.
AI
DI
DOL 12
Summary of Contents for DOL 539
Page 2: ......