Technical manual
31
DOL 278AT
13.5.4 Setting of Climate Computer
13.5.4.1 DOL 234 Jumpers for DOL 278AT Emergency Opening
In connection with the installation of the emergency opening system, the jumpers
of the main module and the I/O module must be set as indicated at the end of the
Setup
/
Show
installation
menu.
See Figure 3 (
E
) for location of jumpers.
NB
The emergency opening system overrules functions only where the jumper is set to ON (e.g.
winch motors and MultiStep
®
steps).
13.5.5 DOL 339 Active Functions when the Control Fails
When installing MultiStep air outlets and high-pressure cooling, you must decide how these functions
are to react in an emergency situation
(Technical
/
Setup
/
Installation
/
Air outlet
).
MultiStep air outlet
Yes
: When the control fails, the air outlet is active.
No
: When the control fails, the air outlet is not active.
Spray cooling
Yes
: When the control fails, spray cooling is active and runs until the
emergency situation is over.
No
: When the control fails, spray cooling is not active.