5 Maintenance instructions
DA 60-920 unit does not require special maintenance. Check on a regular basis wires and pulleys for wear and
tear.
Remember to disconnect the DA 60-820 at the power supply isolator before main-
tenance and cleaning.
Check at least once a year that blades and suspension units are still intact. Call service in case of abnormal
noise and vibration.
Repairs may only be carried out by authorised personnel
5.1 Cleaning
Remove the recirculation fan before cleaning.Open the DA 60-820 unit to 100%.
The net on the recirculation fan must be cleaned regularly as dust and dirt will other-
wise clog the net completely.
Fan
Clean the fan at regular intervals to allow unobstructed air passage.
1. Set the computer to the in-between function
Wash
, (when using a SKOV computer)
2. Clean the ventilation duct.
Remember that fans do not stand high-pressure cleaning.
3. It is recommended that the fan run at 100% for at least one hour after cleaning, in order to dry off any mois-
ture in the fan. If the fan has a tailstock screw in the drain hole it can be removed in this hour.
Motor controller
To ensure sufficient cooling, keep the cooling ribs on the controller dust-free, e.g. by means of compressed air.
Clean the product with a cloth that has been wrung out almost dry in water and avoid using:
• high-pressure cleaner
• solvents
• corrosive/caustic agents
5.2 Recycling/Disposal
Products suitable for recycling are marked with a pictogram.
It must be possible for customers to deliver the products to local collection sites/recycling stations in accordance
with local instructions. The recycling station will then arrange for further transport to a certified plant for reuse,