38
Replacement Procedures
Service Manual
SKOPE OD260
Condenser
Probe
The condenser probe is attached to the side of the condenser coil and
wrapped with insulating cork tape. The condenser probe cable runs along
the floor of the refrigeration unit behind the condenser coil.
To replace the condenser probe
Evaporator
Probe
The evaporator probe is located within the evaporator coil, in-between the
fifth and sixth fins and between the first and second pipes. The evaporator
probe cable runs across the evaporator tub.
1. Remove the front panel, isolate the chiller from the mains power supply and
remove the refrigeration unit (see page 33).
2. Remove the unit LH side
panel.
3. Detach the probe from
the side of the
condenser coil.
4. Remove the electronic controller (see page 36).
5. Detach the condenser probe cable from the rear of the electronic controller
and withdraw the cable (and probe) from the refrigeration unit.
6. Feed the new probe cable (and probe) through the trunking behind the
condenser coil.
7. Reattach the probe and fix to the condenser coil with a cable tie and bundle
any excess cable with another cable tie. Insulate the probe with cork tape.
Evaporator coil
Evaporator
probe cable
Evaporator
probe location