34
Replacement Procedures
Service Manual
SKOPE OD260
Unit Junction
Box
The refrigeration unit connectors and electronic controller are located inside
the unit junction box.
The box is mounted to the front of the refrigeration unit. The interior can be
accessed without removing the refrigeration unit, however this will only offer
restricted access to components. If you need to access other components
or wiring, remove the refrigeration unit prior to accessing the refrigeration
unit junction box.
To open the unit junction box
Condenser
Fan
The condenser fan assembly is made up of a fan blade, a motor and a
bracket. The motor is attached to the bracket fixed onto the condenser coil
shroud. When viewed from the inside of the refrigeration unit (motor end),
the motor and blade should rotate in a clockwise direction and pull air
through the front of the refrigeration unit.
To replace the condenser fan motor
1. Isolate the chiller from the power supply.
2. Remove the cabinet front kick panel. Take care not to scratch the front
upstand when removing.
3. Undo the four fixing screws (two at the top and two at the bottom) from the
front of the unit junction box, and pull the box out from the unit.
4. Undo the four fixing screws (two at the front and two at the back) from the
unit junction box cover and remove the cover.
5. Service as necessary and refit.
1. Isolate the chiller from the power supply and remove the refrigeration unit
from the cabinet (see page 33).
2. Remove the LH and RH unit side
panels.
3. Carefully raise and support the
evaporator tub to gain access to
the condenser fan fixing screws.
4. Gain access to the unit junction
box and trace the condenser fan
flexible cable to the terminal within
the unit junction box. Detach the
condenser fan motor flexible cord
terminals from the terminal block.
5. Undo the two condenser fan
mounting plate screws and
remove the plate and fan as one
assembly.
6. Detach the condenser fan motor from the motor mount and fit the
replacement motor.
7. Reassemble the refrigeration unit and test. When reassembling the
refrigeration unit ensure:
The fan blade is reattached the correct way around.
All wires are attached to the correct terminals within the unit junction box.
The evaporator box is reattached.
Plate and fan
assembly
Evaporator tub
Unit side
panel