![Skope OD1100N Service Manual Download Page 31](http://html1.mh-extra.com/html/skope/od1100n/od1100n_service-manual_1289215031.webp)
31
SKOPE OD1100N
Replacement Procedures
Service Manual
Condenser
Fan
The condenser fan assembly is made up of two high speed electronically commutated (EC)
fan motors, fan blades, mounting brackets, and a mounting plate. These are removed from the
refrigeration cartridge as a complete assembly. The fan blades, fan motors and mounting
brackets can be serviced or replaced if necessary. The condenser fan plug is red.
It is important that fan blades and fan motors are replaced with the same part to ensure safety,
correct alignment and refrigeration performance, and compliance. When refitting or replacing
fan motors, ensure that the blade screw is tightened to 1.5 Nm.
4. Remove 6 × screws from the
electrics box:
•
2 × screws on the left side of the
electrics box
•
1 × screw above the controller
•
3 × screws on the right side of
the electrics box
5. Carefully lift the evaporator tub to
access the electrical sockets.
Disconnect four sockets on the top
left of the electrics box (the
condenser motor and the three
probes) and two on the rear (the
compressor and evaporator fans).
The electrics box can now be
removed.
Procedure 18: To remove the electrics box (continued)
Evaporator tub
Top electrical
sockets
IMPORTANT
Replace the motor with the same SKOPE OEM part.
DO NOT
use alternative parts.
Procedure 19: To access and remove the condenser fan assembly
1. Disconnect the cabinet from the power supply (see page 18).
2. Remove the refrigeration cartridge (see page 28).