27
SERENE SC112G
Replacement Procedures
Service Manual
Evaporator
Fan
The evaporator fan is located on the top level (level three) of the
refrigeration system. It is mounted on the evaporator shroud, on top of the
evaporator tray. The complete fan (motor and blade) is replaced as one
part.
To replace the evaporator fan
Condenser
Fan
The condenser fan is located on the middle level (level two) of the
refrigeration system. It is mounted on the electrics tray. The fan blade and
fan motor can be replaced as individually as necessary.
To replace the condenser fan blade and condenser fan motor
10. Tilt electrics tray up and
support with a block.
Components on level one can now be accessed.
1. Isolate the chiller from the power supply, seperate the top cabinet assembly
from the bottom refrigeration system and gain access to level two of the
refrigeration system (see page 25).
2. Detatch the fan electrics
box, trace evaporator fan
cable to the fan electrics
box and unplug.
3. Detatch the failed
evaporator fan from the
evaporator shroud by
undoing the four fixing
screws.
4. Fit new fan and reassemble. Ensure cables follow original path.
1. Isolate the chiller from the power supply, seperate the top cabinet assembly
from the bottom refrigeration system and gain access to level two of the
refrigeration system (see page 25).