19
SERENE SC112G
Replacement Procedures
Service Manual
Lights
The chiller is lit by four interior pillar lights and two bottom sign lights. All lights
are powered by a 12Vdc LED power supply located within the refrigeration
system (see page 23). If one or several individual light/s fail on a light strip, the
remaining lights will still recieve power and should work. If an LED strip is
damaged (and the circuit broken) no lights will go (including the sign lights). If
all of the lights are off, check operation via the light switch on the electronic
controller (see page 8) before replacing LED strip lighting.
Interior lights
The cabinet interior is lit by four vertical corner pillar LED lights. Each corner
pillar light is made up of two LED strip lights (see page 15 for spare parts).
To replace a single LED interior light strip
1. Isolate the chiller from the power supply by unplugging from the wall socket.
2. Remove the shelves from the chiller.
3. Access the chiller interior
via the appropiate door
and un-clip the diffuser to
expose the failed LED
light strip.
4. Unplug the failed LED
strip and unscrew from the
pillar to remove.
5. Fit the new light and plug into the circuit. Refit the diffuser, refit the shelves
and test.