35
TCE1000N
Replacement Procedures
Service Manual
Unit Cover
Remove the unit cover to access parts within the unit assembly.
To remove the unit cover
Condenser
Fan
The condenser fan assembly is made up of a fan motor, fan blade and
mounting brackets which can be replaced if necessary.
If the fan stops for any reason, check all connections to ensure no plugs
have come loose. Refer to the label on the electrics box cover to identify the
condenser fan plug and socket in the electrics box.
1
4
5
8
9
13
14
15
16
18
20
7
10
11
12
6
19
17
2
3
TCE1000N R290 Junction Box Layout
LAB80224 Rev
. 0.2 May 2020
WARNING
This system contains
ammable refrigerant.
Refer to the Service Manual
before servicing.
Key
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Colour
Description
Key Colour
Description
White – Controller
Black – Heating
Black – Controller Sensor
Red – Evaporator Motor
Blue – Compressor
White – Condenser Motor
Red – Unit Sensor
Yellow – Lighting
1. Disconnect the chiller from the power supply and remove the refrigeration
unit (see page 32).
2. Unscrew the four machine
screws from the sides of
the refrigeration unit and
lift the cover off the unit.
IMPORTANT
Replace the motor with the same SKOPE OEM part.
DO NOT