Positioning the Cabinet

Climate Class

The chiller is designed to operate within a climate class 5 environment (40°C 
@ 40% RH). We recommend that you put the chiller in the coolest place 
possible because it will use less power and last longer.

Chiller

Location

The location of the chiller may be the single most important decision that will 
extend its life and ensure economical, high performance. Allow adequate 
space for the door/s to open and close properly. Self-closing doors have 
internal torsion bars pretensioned at the factory. Ensure the cabinet sits on 
a level surface so that the door shuts and correctly seals, and that the doors 
are unobstructed. Level footing also prevents the condensate tray from 
overflowing.

Power Cord

The chiller has a flexible power cord fitted with a 3-pin plug, which exits the 
rear of the cabinet at floor level. Locate the power cord before the cabinet is 
moved into position so that it is not trapped behind the cabinet.

Ventilation

Ensure there is always at least a 50mm gap around the back, top and 
underside of the cabinet. Keep the ventilation slots in the lower front panel 
clear at all times. 

Never

 store cardboard cartons or other objects in front of 

the chiller.

Before

Operating

Ensure both rear spacers are fully extended outwards and locked into place. 
This will provide the necessary air gap at the rear of the cabinet for correct 
operation. 

CAUTION

To prevent over heating and conserve energy, ensure air flows 

freely all around the chiller - including front, back, top and 

underside (minimum 50mm gap).

Back of chiller

Rear spacer

Summary of Contents for BME1200-AC

Page 1: ...BME ActiveCore User Manual MAN11080 Rev 3 2 Oct 2015 BME1200 AC SKOPE Bottom Mount Vertical Chiller...

Page 2: ...535 Australia 0800 947 5673 New Zealand SKOPE 1 year Extended Warranty Extend your Warranty Protection by 1 year during registration Please check you have not already organised an extended warranty th...

Page 3: ...2 Operation Automatic Start Up 10 Lighting 10 LED Tube Side Light 10 LED Modular Shelf and Side Lighting 10 Sign Light 10 Loading Product 11 Electronic Controller 12 Introduction 12 Faceplate 12 Norma...

Page 4: ...careful not to touch moving parts and hot surfaces For your own safety and that of others ensure that all electrical work is done by authorised personnel If the power supply flexible cord becomes dam...

Page 5: ...ooting also prevents the condensate tray from overflowing Power Cord The chiller has a flexible power cord fitted with a 3 pin plug which exits the rear of the cabinet at floor level Locate the power...

Page 6: ...at each end of the handle Rotate the handle so that the spring clips point up 3 Locate both of the handle mounts onto the brackets on the front of the door and push the handle down onto the brackets...

Page 7: ...through the holes on the inside of the door frame and remove the handle 3 Remove the bracket s from the handle mount by pressing the bracket in and down until it unclips from the handle mount 4 Fit an...

Page 8: ...d shelf position The support strips are numbered for easy location of shelf clips View the numbers in the bottom LH corner of the shelf clip To fit a shelf clip To slide a shelf clip up and down To re...

Page 9: ...below To reposition shelves fitted with lights 1 Isolate the chiller from the power supply see Isolating Electrics on page 15 2 Remove product from the shelf required to be moved and from the shelf im...

Page 10: ...mponent is suspected of being faulty a service call should be arranged so that a replacement component can be fitted Sign Light Cabinets with a lit sign are fitted with an LED tube located inside the...

Page 11: ...space around each item to ensure even cooling and efficient operation of the chiller Do not exceed a maximum load of 20kg per shelf Remove some product if the shelves are flexing Do not let anything...

Page 12: ...thorised service agent ES 1 2 3 4 5 6 8 7 No Item Description 1 Digital display of cabinet temperature or messages The temperature is what the sensor inside the chiller detects and not necessarily the...

Page 13: ...net lights on and off 1 Press and hold the set button for 3 seconds until PS is shown on the display indicating entry into the controller settings menu 2 Press the down button to scroll the menu until...

Page 14: ...isplay 3 Press the set button The current setpoint value is shown on the display 4 Press the up or down button to increase or decease the setpoint value to the required temperature 5 Press the set but...

Page 15: ...unit compartment To isolate the electrics 1 Open the door and undo the fixing screws from the top of the front kick panel Pull the kick panel out to remove Note The electronic controller is attached t...

Page 16: ...enser coil The optional filter is disposable and should be replaced when it shows signs of wear Do not apply hot water blow dry or place in dishwasher To clean the optional filter WARNING Isolate the...

Page 17: ...er coil 1 Remove the front panel and isolate the chiller from the power supply see Isolating Electrics on page 15 2 Brush the condenser coil with a soft brush to remove any dust and fluff 3 Turn the i...

Page 18: ...Sign Light BME600 AC and BME1200 AC chillers are fitted with a lit sign In the event of sign light failure a service call should be arranged so that a replacement LED tube can be fitted IMPORTANT DO...

Page 19: ...aceplate or open the door Lights switched off Switch light on by pressing the light button on the electronic controller faceplate Failed LED tube Replace LED tube see page 17 Failed LED shelf light Co...

Page 20: ...oduct after their state condition get up or packaging has been altered in any manner Alters removes including part removal or obliterates including part obliteration the trade mark on the product Appl...

Reviews: