Servicing
Isolating Electrics
The chiller
MUST
be isolated from the power supply before attempting
any
maintenance. Either unplug the cabinet from the wall or use the isolation
switch to turn off electrics to the cabinet and refrigeration unit. The isolation
switch is located behind the cabinet front kick panel, on the right-hand side
of the refrigeration unit compartment.
To isolate the electrics
1. Open the door and undo the fixing screws from the top of the front kick panel.
Pull the kick panel out to remove.
Note:
The electronic controller is attached to the front kick panel. Take care of
cables when removing the front kick panel.
2. Switch off (O) the power at the isolation switch, located on the right-hand side
of the refrigeration unit compartment.
3. Once the maintenance work has been completed, remember to turn the
isolation switch back on (I) before refitting the front kick panel.
Isolation switch
Electronic controller
Front kick panel (removed)
Door (open)