13
SKOPE BME ActiveCore
Operation
User Manual
Normal and
Energy Saving
Modes
The electronic controller is programmed to run the chiller in ‘Normal’ mode
or ‘Energy Saving’ mode.
When plugged in, the chiller will run in ‘Normal’ mode. If the front door/s are
not opened for a specified time period (default setting is three hours), the
electronic controller will switch the chiller from ‘Normal’ mode to ‘Energy
Saving’ mode and the cabinet lights will turn off. The electronic controller will
switch the chiller back into ‘Normal’ mode when a door is opened, or after a
specified time period (default setting is nine hours) in ‘Energy Saving’ mode.
To manually switch the chiller between ‘Normal’ and ‘Energy Saving’ modes,
press and hold the Energy Save (up) button on the electronic controller
faceplate.
To change the default times for automatic switching between ‘Normal’ mode
and ‘Energy Saving’ mode, follow the procedures below.
To change the time between ‘Normal’ and ‘Energy Saving’ modes
Lights
When in ‘Normal’ mode the cabinet lights are on. When in ‘Energy Saving’
mode the cabinet lights are off. Press the Light button on the electronic
controller faceplate to manually switch the cabinet lights on and off.
1. Press and hold the
set
button for 3 seconds until
PS
is
shown on the display, indicating entry into the controller
settings menu.
2. Press the
down
button to scroll the menu until
r6
is
shown on the display.
The
r6
value is the time (in hours) without the door
being opened. When this time is reached (during store
closing hours or quiet periods) the electronic controller
will switch the chiller from ‘Normal’ mode to ‘Energy
Saving’ mode. The
r6
value must be
≥
1 hour.
IMPORTANT
Do
not
set r6 to 0.
3. Press the
set
button. The current
r6
value (in hours) is shown on the display.
4. Press the
up
or
down
button to increase or decease the value (in hourly
increments).
5. Press the
set
button to temporarily save the new
r6
value.
6. Press the
down
button to scroll the menu until
r7
is
shown on the display.
The
r7
value is the maximum time (in hours) that the
chiller will stay in ‘Energy Saving’ mode. When this time
is reached the electronic controller will switch the chiller
from ‘Energy Saving’ mode to ‘Normal’ mode.
7. Press the
set
button. The current
r7
value (in hours) is shown on the display.
8. Press the
up
or
down
button to increase or decease the value (in hourly
increments).
9. Press the
set
button to temporarily save the new
r7
value.
10. Press and hold the
set
button for 3 seconds to permanently save the new
values and exit the controller settings menu.