background image

GDS101

Replacement procedure

This instruction leaflet will help you change the unit without loosing your settings. Follow 

the guide step by step.

Estimated time: 10 - 30 minutes

It is recomended that you take a photo of your wiring, and photo or print of the status screen 

(Screen 9) before you start.

Fill in your values in the yellow part of the table. (If the same as default value, you do not 

need to fill in)

To get to the Setup Menus press and hold 

SDBGDS101_30

Summary of Contents for GDS101

Page 1: ...ide step by step Estimated time 10 30 minutes It is recomended that you take a photo of your wiring and photo or print of the status screen Screen 9 before you start Fill in your values in the yellow...

Page 2: ...icated frequency of lower frequency channel see chapter 5 Low frequency indication Soft Key 2 LANGUAGE English etc Screen language selection Soft Key 3 DEPTH m etc Unit of measurement for depth Soft K...

Page 3: ...38kHz Channel can be factory modi fied to these frequencies This is not normal on ex change units Only available if you have selected the lowest frequency on screen 3 J100 Pin Pin 38 kHz Language Disp...

Page 4: ...ulse input calibration Soft Key 2 ENABLE pos neg select polarity of external sync signal remote sounding control option Soft Key 3 NMEA OUT async 1s Select between synchronous with sampling rate synch...

Page 5: ...E Selects the rate J100 Pins 6 7 FWD ENABLE External synchronise ONLY Special Navy version J100 Pins 12 13 positive NMEA OUT How often to send NMEA every second or when a ping comes 9pin D Type 1S UPP...

Page 6: ...NMEA Communication Settings...

Page 7: ...sage What it shows Is it used Place tick Default DPT Message Depth below keel and surface ON DBS Message Depth below surface OFF DBT Message Depth Below Transducer not reco mended OFF DBK Message Dept...

Page 8: ...P DeskJet Epson Lq300 Epson D88 Built in thermal printer Select type off printer that are connected Soft Key 3 FIX RANGE on off Limit Search Range to Window on FIX RANGE gives better detection in case...

Page 9: ...e reco mended OFF Alarm Internal buzzer enable OFF Vessel The displayed vessel on the screen merchant 1 This screen contains the settings for all the other interfaces analogue pulse and alarm Place a...

Page 10: ...LOCATION Pos not installed Pos is default setting If NOT installed is selected for one of the Frequenses it will not be available in screen 2 soft key 2 Fwd Aft Port Strb To select position of transdu...

Page 11: ...in 26 28 Location FWD AFT PORT STRB POS Transducer 200 provides a voltage or current out to external repeaters sys tems J100 Pin 32 34 Location FWD AFT PORT STRB POS Power Max output power Low frequen...

Page 12: ...Take a picture of the wiring before you start and the setup screens Fill in relevant information in the yellow areas Note the colours in the table opposite If you have cables with the same colour mar...

Page 13: ...arm common 19 4 Alarm NO 20 Analog depth 10v 5 Alarm NC 21 Analog Ref 6 Pulses 100 200 p NM speed in 22 Analog Depth 4 20mA 7 Pulses 100 200 p NM speed in 23 Analog Ref 8 24 9 25 10 Remote Keyb Remote...

Page 14: ...use this on the new cabinet and re mount Replace the wires as before Power on Press the left and right soft key until the unit beeps 4 times master reset Go through the setup screens and reset the un...

Reviews: