Skipala DIGR-1502/E User Manual Download Page 1

 
 
 
 
 

 

USER MANUAL FOR 

DIGR-1502/E CONTROLLER  

 

 

 

 

Version: 1.3 

October 2018 

 

 

Summary of Contents for DIGR-1502/E

Page 1: ...USER MANUAL FOR DIGR 1502 E CONTROLLER Version 1 3 October 2018...

Page 2: ...Description 3 3 Connection 7 4 Operating status 11 5 Activation 11 6 R run S stop 12 7 Setting and saving parameters 12 8 Description of parameters 12 9 Maintenance 22 10 Disposal 22 11 Guarantee 22...

Page 3: ...controller is designed for control of vibration feeders driven with an electromagnetic coil Two basic parameters i e output voltage amplitude and frequency are controlled The operation of the controll...

Page 4: ...or R run condition enter Saving the set values Increase displayed value Decrease displayed value Browsing through parameters upward Browsing through parameters downward on off Controller turning on of...

Page 5: ...5 23 Fig 2 Basic dimensions 66 00 120 00 130 00 28 50 167 00 192 00 6 50 110 00 105 00...

Page 6: ...6 23 Fig 3 Connection of controller external parts supply drive internal source...

Page 7: ...ection provided by the device may be compromised 3 1 Installation The controller can be installed either in the horizontal position or in the vertical position with outlets facing downward Caution The...

Page 8: ...ng of the cap To allow better access to the terminal block we recommend dismounting also the part with outlets Fig 5 Fig 5 Removal of the part with outlets There are connecting terminals under this li...

Page 9: ...connection is made by a flexible cable of 3x 1 5 mm2 which is triggered by a circuit breaker with a maximum rated current of 16A characteristic B This installation must be equipped with a disconnecti...

Page 10: ...sensors valves digital and analogue signals as required by a specific application in accordance with Fig 3 Detailed explanation please see Section 8 7 The inputs and outputs are fed with safely separ...

Page 11: ...er is idle The controller waits for a signal from sensors or from a master control system Viewing and modifications of all parameters are possible 5 Turning ON Controller turning on can be carried out...

Page 12: ...d in the memory at once It is recommended to save in the S stop status First locked parameters must be unlocked by typing the password parameter A41 Chapter 8 28 8 Description of parameters The contro...

Page 13: ...r can be used when starting and running down the feeder to change the value of the amplitude so that the feeder starts to run fluently The setting range is 0 6 s The time relates to starting from 0 to...

Page 14: ...um stock The sensor is connected to the input monitoring the maximum stock in the storage tank being filled by the feeder If the sensor is active during the period stated by the parameter A13 the feed...

Page 15: ...ter 8 8 8 11 A23 Analogue AIN Determining the use of analogue input AIN It can be configured as analogue 0 10V or digital 0 24V Not used The input is not used Amplitude The input is configured as anal...

Page 16: ...drive is in the R run status Air jet The output controls the air supply valve into the feeder The valve is switched on before activation of the feeder The time is set using parameter A25 Timer T11 Wh...

Page 17: ...tivity of the ejector E2 Monitor IN1 ON The output monitors the activated status of digital input IN1 This is only monitored when the drive is in the status RUN operating If during the period set by p...

Page 18: ...ned by setting parameter A24 output OUT1 8 15 A27 Timer T13 Universal timer where the use is determined by setting parameter A24 Output OUT1 8 16 A28 Output OUT2 Determining the use of digital output...

Page 19: ...8 24 A37 Service functions For servicing Not used Service functions are not activated RND stop When testing the feeder actual operational behaviour can be simulated The feeder is disconnected and con...

Page 20: ...can not be changed Its purpose is to protect the controller against accidental overwriting of locked parameters The password cannot be typed if it is changed or the controller disconnected 8 29 Factor...

Page 21: ...MAX 100 0 18 Ampl MIN 05 0 19 Input IN1 not used 20 Sensor 1 type normal open 21 Input IN2 not used 22 Sensor 2 type normal open 23 Analogue AIN not used 24 Output OUT1 not used 25 Timer T11 00 0 s 26...

Page 22: ...for repair When changing the fuse observe the prescribed T8A value Tip for you In the case of complications with the operation of the controller reset the factory setting of the parameters Chapter 8 2...

Page 23: ...Council 2014 35 EU Government Directive No 117 2016 Coll Directive of the European Parliament and the Council 2014 30 EU Description of the product The product is designed for regulating vibration fee...

Page 24: ......