USER MANUAL FOR 

DIGR-1202/E 

CONTROLLER  

 

 

 

 

Version: 1.4 

July 2015 

Summary of Contents for DIGR-1202/E

Page 1: ...Karel Skipala Automating manufacturing processes modernising machine control producing industrial electronics http www skipala cz USER MANUAL FOR DIGR 1202 E CONTROLLER Version 1 4 July 2015...

Page 2: ...Description 3 3 Connection 7 4 Operating status 10 5 Activation 10 6 R run S stop 10 7 Setting and saving parameters 11 8 Description of parameters 11 9 Maintenance 21 10 Disposal 21 11 Guarantee 21...

Page 3: ...ting vibration feeder driven by an electromagnetic coil The basic regulation value is the output voltage The controller can be used for quickly setting the oscillations frequency 100 Hz 50 Hz 33 Hz Th...

Page 4: ...s stop run transfer into the status S stop or R run enter saving adjusted values increase the displayed value decrease the displayed value browsing in parameters upwards browsing in parameters downwar...

Page 5: ...5 22 Fig 2 basic dimensions 66 00 120 00 130 00 28 50 167 00 6 50 110 00 105 00 195 00...

Page 6: ...6 22 Fig 3 connecting the external part of the controller 230V 50Hz supply INTERNAL SOURCE drive A...

Page 7: ...firm part of the equipment without direct vibrations Drill 4 x 4 2 mm diameter holes with M5 threads into the base plate on which the controller is mounted Fig 2 shows the spans of the holes Clamp the...

Page 8: ...necting terminals 3 3 Connecting the power part The controller has an internal T8A circuit breaker which protects the device against short circuits not against overloading Select the series protection...

Page 9: ...n the other conductors Fig 7 termination of power cables Fig 8 connecting conductors to terminals 3 4 Connecting the control part Cross section of conductors 0 08 0 5 mm2 Diameter of the cable 3 6 5 m...

Page 10: ...nal from the sensors or from the master control system All parameters can be browsed and edited 5 Activation The controller can be activated in two ways which are determined by setting parameter A36 C...

Page 11: ...this type of controller 8 2 A11 Amplitude Setting the value of the output voltage and the intensity of vibrations of the feeder from 20 100 with 0 5 steps The setting range can be restricted by the va...

Page 12: ...batches Use parameter A15 to set the time during which the batch is supplied parameter A16 the time of the pause between batches 8 6 A17 Amplitude maximum limit A18 Amplitude minimum limit Use these p...

Page 13: ...y setting parameters A12 A13 properly only one sensor is sufficient for monitoring the storage tank Minimum reserve This setting is only used if the second output is defined as the maximum reserve The...

Page 14: ...need to decrease the speed of the feeder during the activity For example when pouring material on the scale when approaching the desired weight Start The input is configured as digital The supply of...

Page 15: ...e timeout so that the ejector does not respond to short impulses from the sensor Use Timer T12 parameter A26 batch OFF to change the ejection time Fig 9a activity of the ejector E1 Ejector E2 Fig 9b i...

Page 16: ...from status 1 into status 0 are suppressed by setting parameter A26 Timer T12 All impulses which are shorter than the set time will be ignored Tip for you This setting can be used for example if conn...

Page 17: ...2 T13 parameters A25 A26 A27 uses output OUT2 timers T21 T22 T23 parameters A29 A30 A31 8 17 A29 Timer T21 Universal timer where the use is determined by setting parameter A28 Output OUT2 8 18 A30 Tim...

Page 18: ...ord Typing the password temporarily unlocks blocked parameters The password is delivered by the firm as a 3 digit number 108 and can not be changed Its purpose is to protect the controller against acc...

Page 19: ...sit our Internet pages http www skipala cz 8 29 Factory settings If there are complications with controller RESTART it to reset the factory settings of all parameters RESTART as follows Disconnect the...

Page 20: ...pl MAX 100 18 Ampl MIN 20 19 Input IN1 not connect 20 Sensor 1 type NO 21 Input IN2 not connect 22 Sensor 2 type NO 23 Analogue AIN not connect 24 Output OUT1 not connect 25 Timer T11 00 0s 26 Timer T...

Page 21: ...controller to the manufacturer for repair Tip for you In the case of complications with the operation of the controller reset the factory setting of the parameters Chapter 8 29 10 Disposal At the end...

Page 22: ...ive of the European Parliament and the Council 2004 108 EC Description of the product The product is designed for regulating vibration feeders driven by an electromagnetic coil List of technical and h...