![Skil-Care BedPro Under Mattress Safety Alarm Manual Download Page 1](http://html1.mh-extra.com/html/skil-care/bedpro-under-mattress-safety-alarm/bedpro-under-mattress-safety-alarm_manual_1288439001.webp)
Safety Alarm Unit
29 Wells Ave, Yonkers, NY 10701
914.963.2040 • toll-free: 800.431.2972 • www.skil-care.com
29 Wells Ave, Yonkers, NY 10701
914.963.2040 • toll-free: 800.431.2972 • www.skil-care.com
H
H
G
UnderMattress
UnderMattress Replacement Sensor Pads
OverMattress Replacement Sensor Pads
Early Warning UnderMattress Replacement Sensor Pads
*P= 11.5” Cord
Early Warning
SYSTEM OPERATION
SENSOR PAD SETUP
SENSOR PAD SETUP
This alarm features an under-mattress sensor pad that is
protected against incontinence and wear by the mattress.
Unlike sensor pads that are placed on the mattress, the BedPro
UnderMattress sensor will not compromise the pressure
relieving qualities of the mattress. Placed beneath the mattress,
the BedPro sensor pad stays in place to reduce false alarms.
This is especially important for restless residents.
System Operation for when the BedPro UnderMattress, Early Warning UnderMattress or
OverMattress sensor pads have been properly installed.
Whenever the alarm is initiated, pressing the “Auto-Reset” button on top of the alarm unit will silence it. Pressing this button
puts the system into stand-by mode. The system will automatically go into monitoring mode when you put your resident to bed.
There’s no need to remember to turn the system on. Skil-Care recommends the following procedure for using the BedPro
UnderMattress, Early Warning UnderMattress and OverMattress Safety Alarm System.
• Press “Power Test” button before putting resident to bed. If “In-Room Alarm” switch is set to the “Hi or Low” position, the
alarm signal will sound and the LED will flash while the button is held down. If the “In-Room” switch is to the “Off” position,
the LED will flash while the button is held down. If the LED and/or alarm signal are not activated when the button is pressed,
check the power source connections. If alarm is on battery, replace both AA batteries. Do not use alarm system if pressing
“Power Test” button cannot activate LED and/or alarm signal.
• Place resident in bed. The LED should flash indicating that the alarm is in the monitoring mode. If LED does not flash,
remove resident from the bed and examine sensor pad. If pad is damaged, replace it. Do not use alarm system if LED does
not flash when resident is in bed.
• If alarm is set to signal both at bedside and at the nurse’s station, select the preferred sound option using the selector switch
on the top of the alarm unit. Adjust the high/low toggle on the back.
• If your resident leaves the bed and then returns, the alarm will silence and the system will reset itself. Be certain to visit the
resident to make sure he/she is safe.
• Press the “Auto-Reset” button after you have removed your resident from the bed. This will place the system in the
stand-by mode.
Keep a copy of these instructions in your procedures manual. If you require extra copies of these instructions,
call Skil-Care at 1-800-431-2972 or go to skil-care.com and click on “Product-Use Instructions.”
Sensor Pad Setup for BedPro Early Warning UnderMattress System (contd.)
3.
Pass sensor cable under headboard and tuck it under the Cable Strain-Relief tab before
inserting the plug into the Modular Connection (Illustration H). The strain-relief tab prevents
the plug from being accidentally dislodged and damaged. Be certain to keep cable away from
side rails and out of resident’s reach. Keep cord away from side rails and out of resident’s reach.
4.
Place sensor pad on bed.
5.
Sensor pad may be cleaned with a damp cloth and mild cleanser. Do not immerse pad in water or
cleaning solution. Do not sterilize.
6.
Inspect pad before each use. Replace if damaged.
Read “Warnings” on sensor pad
Important:
This UnderMattress sensor is designed to work with most mattresses and beds.
However, due to differences in mattress construction, bed designs , and resident weight, this
sensor pad may not work in all situations. Be certain to evaluate the alarm system’s operation
for each bed and resident. If it does not work, you may want to consider Skil-Care’s BedPro OverMattress sensor pad.
Proceed to “System Operation” on page 6. See page 6 for information about ordering replacement sensor pads.
Sensor Pad Setup for BedPro OverMattress System
1.
Remove bed sheet and place sensor pad across width or length of bed (Illustration G).
2.
Position connector cable toward headboard. The opposite end must be positioned below
the resident’s pelvis.
3.
Pass sensor cable under headboard and tuck it under the Cable Strain-Relief tab before
inserting the plug into the Modular Connection (Illustration H). The strain-relief tab prevents
the plug from being accidentally dislodged and damaged. Be certain to keep the cable away
from side rails and out of resident’s reach. Keep cord away from side rails and out of resident’s reach.
4.
Cover mattress and sensor pad with sheet.
5.
Sensor pad may be cleaned with a damp cloth and mild cleanser. Do not immerse pad in water
or cleaning solution. Do not sterilize.
6. Inspect pad before each use.
Read “Warnings” on sensor pad
Proceed to “System Operation” on page 6. See page 6 for information about
ordering replacement sensor pads.
All BedPro replacement sensor pads are available from your medical products supplier.
All BedPro sensor pads may also be used with Skil-Care’s new MultiPro Alarm
6
5
1
You may also order the BedPro Alarm Unit with Accessories (nurse-call connector cable, A/C adaptor and Y-connector).
See BedPro Alarm Control Unit with Accessories on page 1 for more detail.
This alarm system features a unique under-mattress sensor pad
that is designed to activate an alarm signal before the resident
exits the bed. The diagonally tapered sensor pad initiates the
alarm when the resident sits on or moves toward the edge of the
bed. Placed beneath the mattress, the sensor will not
compromise the pressure relieving qualities of the mattress.
The mattress protects the sensor pad against incontinence,
resident tampering, and incontinence.
1. The
BedPro Alarm Systems
are not substitutes for proper supervision. Staff on a regular basis must monitor fall-risk and
wander-risk patients/residents.
2. If batteries are used as the source, batteryt power must be checked each time the alarm is used to monitor the resident.
If battery power is weak, the two AA batteries must be replaced. The alarm will sound if batteries are weak.
3. The LED should flash when the alarm is powered, and the resident is in bed, on top of the sensor pad. If the LED fails
to flash and you are using the A/C adaptor, check connections at wall outlet and alarm unit. If you are using battery power,
replace the two AA batteries. If the LED fails to flash after connections have been checked or the batteries replaced,
discontinue use of alarm.
Alarm unit and sensor pads made in China. Instructions printed in U.S.A
The
BedPro Safety Alarm Control Unit
is replacement
guaranteed for one year following the date of purchase
These guarantees cover defects in materials and
workmanship under conditions of normal use. Please
return defective part to dealer from whom it was
purchased. The dealer will send the defective part to
Skil-Care and arrange for shipment of a replacement.
GUARANTEES
CAUTIONS
OverMattress
OverMattress
Alarm Control
Safety Alarm
Under Mattress Safety Alarm
Safety Alarm
Safety Alarm
Unit with Accessories
Replacement Sensor Pads
Reorder#
Description
Unit
909310
BedPro OverMattress Safety Alarm with
10”x30” Sensor Pad - 45 Days
Set
909311
BedPro OverMattress Safety Alarm with
10”x30” Sensor Pad - 180 Days
Set
Reorder#
Description
Unit
909320
BedPro UnderMattress Safety Alarm with
10”x30” Sensor Pad - 90 Days
Set
909321
BedPro UnderMattress Safety Alarm with
20”x30” Sensor Pad - 90 Days
Set
909322
BedPro UnderMattress Safety Alarm with
10”x30” Sensor Pad - 180 Days
Set
909323
BedPro UnderMattress Safety Alarm with
20”x30” Sensor Pad - 180 Days
Set
909340
BedPro UnderMattress Safety Alarm with
10”x30” Sensor Pad - 1 Year
Set
909341
BedPro UnderMattress Safety Alarm with
20”x30” Sensor Pad - 1 Year
Set
909343
BedPro UnderMattress Safety Alarm for
Light Mattresses 39-42lbs. - 2 Year
Set
Reorder#
Size
Reorder#
Size
Guarantee
Unit
909325
10” x 30”
909328
20” x 30”
90 Days
Ea.
909326
10” x 30”
909329
20” x 30”
90 Days
5/pk
909327
10” x 30”
909330
20” x 30”
90 Days
10/pk
909331
10” x 30”
909337
20” x 30”
180 Days
Ea.
909332
10” x 30”
909338
20” x 30”
180 Days
5/pk
909333
10” x 30”
909339
20” x 30”
180 Days
10/pk
909401
10” x 30”
909403
20” x 30”
One Year
Ea.
909402
10” x 30”
909404
20” x 30”
One Year
10/pk
909345
For Light Mattresses 39-42lbs.
Two Years
Ea.
Reorder#
Guarantee
Reorder#
Guarantee
Size
Unit
909314
45 Days
909317
180 Days
10” x 30”
Ea.
909315
45 Days
909318
180 Days
10” x 30”
5/pk
909316/P*
45 Days
909319
180 Days
10” x 30”
10/pk
Reorder#
Guarantee
Reorder#
Guarantee
Length
Unit
909304
90 Days
909307
180 Days
30”
Ea.
909305
90 Days
909308
180 Days
30”
5/pk
909306
90 Days
909309
180 Days
30”
10/pk
Reorder#
Description
Unit
909301
BedPro Early Warning System with
30-inch-long sensor pad - 90 Days
Set
909302
BedPro Early Warning System with
30-inch-long sensor pad - 180 Days
Set
Reorder#
Description
Unit
909310
BedPro OverMattress Safety Alarm with
10”x30” Sensor Pad - 45 Days
Set
909311
BedPro OverMattress Safety Alarm with
10”x30” Sensor Pad - 180 Days
Set
Sensor Pads
45 Day 90 Day 180 Day 1 Year 2 Years
BedPro UnderMattress
a
a
BedPro Early Warning
a
a
a
a
BedPro OverMattress
a
a
Reorder#
Description
Unit
909334
BedPro Electronic Unit without Accessories
Ea.
909335
BedPro Electronic Unit with Accessories
Set
909336
BedPro Electronic Unit with Accessories
10 Pk
Rev: 062017