Section 06
ELECTRICAL
Subsection 06
(TESTING PROCEDURE)
06-06-5
1. 3-01 housing
5. Compare readings with those appearing in the
IGNITION table.
7. HIGH VOLTAGE COIL VOLTAGE
TESTING
1. Disconnect spark plug cap from spark plug.
2. Fasten alligator clip to spark plug cable, near
the spark plug.
3. Connect other multimeter wire to engine (ground),
then place selector switch to
and scale to
0.00
VAC
.
4. Activate the manual starter and check values in-
dicated by the multimeter.
5. Repeat operation 3 times.
TYPICAL
6. Compare readings with those appearing in the
IGNITION table.
8. MPEM SUPPLY VOLTAGE
TESTING
Grand Touring 700/SE only
1. Disconnect the 10-05 and 10-01 housings be-
tween module and main harness.
2. Connect multimeter probes to RED/BLUE and
BLACK wires coming out from harness. Place
the selector switch to
and the scale to
00.0
VAC
.
3. Activate the manual starter and check values in-
dicated by the multimeter.
4. Repeat operation 3 times.
1. 10-01 housing
2. 10-05 housing
5. Compare readings with those appearing in the
IGNITION table.
9. MPEM TESTING
Grand Touring 700/SE Only
1. Disconnect the MPEM.
2. Install a known-good MPEM directly (
not to the
main harness
). Connect DESS switch, trigger
coil, high tension coils, ground (black wire of
10-01 housing), 10-05 housing to the diagnostic
housing.
A30E0QA
1
V
˜
A05E0DA
V
˜
A30E0RA
1
2
Summary of Contents for Formula MACH 1
Page 1: ......
Page 277: ...FORMULA 111 600 600 R 600 LT 700 700 R MACH 1 1 R ANNEX 1...
Page 278: ......
Page 279: ......
Page 280: ......
Page 281: ......
Page 282: ......
Page 283: ...MACH Z Z R Z LT Z LT R ANNEX 2...
Page 284: ......
Page 285: ......
Page 286: ......
Page 287: ......
Page 288: ......
Page 289: ...GT 700 ANNEX 3...
Page 290: ......
Page 291: ......
Page 292: ......
Page 293: ......
Page 294: ......
Page 295: ......
Page 296: ...GT SE ANNEX 4...
Page 297: ......
Page 298: ......
Page 299: ......
Page 300: ......
Page 301: ......
Page 302: ......
Page 303: ......
Page 304: ......