Protection
Measurement Types
SKF Multilog On-Line System IMx-M
2 - 19
User Manual
Trigger Physical Interface
The digital input is used to acquire the speed and the trigger point phase reference.
Using One Tacho Signal Source as Trigger to Many Triggered
Measurements
When there is a need for triggering several Piston rod drop measurements,
distributed over several analog channel pairs, from one single phase reference
transducer / tacho sensor the following approach shall be deployed.
1.
Connect the sensor to one digital input
2.
Connect the remaining digital inputs to the buffered digital output
associated with the digital input at which the sensor is connected.
Note
: Make sure the digital inputs are correctly configured as described
Figure 2 - 13.
Distributing One Tacho Signal Source to Several Digital Inputs.