Protection
Protection Module Configuration with IMx-M Manager
SKF Multilog On-Line System IMx-M
2 - 101
User Manual
Stop bits
defines the number of bits terminating a transmission which can be 1 or
2.
Configuring Network Settings (CMM)
Each slot requires network parameters to be set before a network configuration (*.imx)
file can be created and saved, ready for the USB download to the condition monitoring
module.
Network
defines how the IP settings are to be configured. There are 3 different ways to
set the IP settings.
Use fixed IP Address
allows to enter IP Address, subnet mask and primary
gateway of the IP settings manually. This option must be used with a great
care not to duplicate an existing address which can result in both devices being
locked from communicating over the network.
Figure 2 - 78.
Assigning the S
lot
a Fixed IP Address.
Hardware switches
means that the network configuration is done by setting
HEX rotary switch manually. The HEX rotary switch for IMx-M is located inside
the rack, back of the right-most panel (looking at the rack from the front
panel).
For the network configuration by hardware switches, the following logic must
be fulfilled.