Quick Setup/Installation Guide for Lubrication Monitor Controller LMC 301
951-150-029-EN
4
All relevant persons (operating personnel,
supervisors) must be informed of the activity
prior to beginning work.
Precautionary operational measures / work
instructions must be observed.
o Take appropriate measures to ensure that
moving/detached parts are immobilized
during the work and that no body parts can
be pinched by unintended movements.
o Assemble the product only outside the
operating range of moving parts, at an ade-
quate distance from sources of heat or cold.
o Prior to performing work, the product and
the machine/system in which the product
will be integrated must be depressur-
ized and secured against unauthorized
activation.
o All work on electrical components may be
performed only with voltage-insulated
tools.
o Fuses must not be bridged. Always replace
fuses with fuses of the same type.
o Ensure proper grounding of the product.
o Drill holes required for assembly only on
non-critical, non-load-bearing parts.
o Other units of the machine/the vehicle must
not be damaged or impaired in their func-
tion by the installation.
o No parts of the centralized lubrication sys-
tem may be subjected to torsion, shear, or
bending.
o Use suitable lifting gear when working with
heavy parts.
o Avoid mixing up/incorrectly assembling dis-
assembled parts. Label parts.
o The installation of the cable glands and the
customer provided cord sets to be done by
the customer. The customer is responsible
for proper installation.
o Cable glands and conduits -see Operating
instruction, chapter 10-Accessories.
o When mounting the customer connecting
cable no rigid connection pipe must be used
- see page 8, Fig. 1, sign (1) on the
controller ground
1.6 Assembly/maintenance/malfunction/
decommissioning/disposal
1.7 Intended use
The Lubrication Monitor Controller is used to
control up to three pumps, each with a one-
to-three-zone (one to three main lines)
SKF Centralized lubrication system.
LMC 301 designs 86501 and 86503 (IO
module) are powered via
100 to 240
VAC
mains provided by the customer. They must
be connected in accordance with DIN, VDE
regulations.
LMC 301 designs 86500 and 86502 (IO
module) are powered via 24 V DC.
The technical information contained in these
instructions must be followed.
Any other usage is deemed non-compliant
with the intended use.
1.8 Foreseeable misuse
Any usage of the product differing from the
aforementioned
conditions and stated purpose is strictly
prohibited.
Particularly prohibited are:
Use for other control tasks
o Use in an explosion protection zone
o Use to feed, forward, or store hazardous
substances and mixtures as defined in An-
nex I Part 2-5 of the CLP Regulation
(EC 1272/2008)
o Use to feed / forward / store gases, lique-
fied gases, dissolved gases, vapors, or fluids
whose vapor pressure exceeds normal at-
mospheric pressure (1013 mbar) by more
than 0.5 bar at their maximum permissible
operating temperature
The manufacturer shall not be held liable for
damage resulting from:
o Failure to comply with these instructions
o The use of lubricants/media not approved
for the unit type
o Contaminated or unsuitable lubricants
o Installation of non-original SKF
components
o Non-compliant usage
o Improper assembly, configuration or filling
o Improper reaction to malfunctions
o Non-observance of maintenance intervals
o Independent modification of system
components
1.9 Disclaimer of liability
1.10 Referenced documents
In addition to this manual, the following docu-
ments must be observed by the respective
target group:
o Operational instructions / approval rules
o Instructions from suppliers of purchased
parts
o Manual for the insulation resistance tester
o Project planning documents and other rel-
evant documents
The operator must supplement these docu-
ments with applicable regulations for the
country of use.
The documentation must be included if the
product is transferred to a new operator.