![SKF IPM 12 Operating Instructions Manual Download Page 97](http://html1.mh-extra.com/html/skf/ipm-12/ipm-12_operating-instructions-manual_1287095097.webp)
Page 97
EN
Autoreset bei Alarm
Step
Key
Function
1
LED test
Press
RES
et key
The LED test runs automatically.
2
BCD test
Press
SERV
ice key
The BCD test (address test) runs automatically..
3
Test of the pulse inputs
Press
SEL
key
The pulse inputs are checked.
4
EEPROM-Test and save
Press the
MEM
ory key
The EEPROM test is performed. The version number is then automati-
cally saved and after that the PON started. The default values are loaded
.
RES
SERV
SEL
MEM
10. Service
10. Service
10.1 IPM 12 Hardware test
If a key on the control panel of the IPM 12
pulse meter is pressed while the power is
<ON>, the device to be checked goes into the
hardware mode..
All entered setup values are over ridden
by the default values.
All hardware tests can be performed in the
hardware mode.
The following settings can be made on the
IPM 12 pulse meter:
Auto-reset in the event of an alarm
No auto-reset in the event of an alarm
Lock/release
MEM
ory key
The setup values must be reentered after the
hardware test (- see setup/actual value
comparison- 7.1.2)..
10.1.1 Auto-reset in the event of an alarm (IPM 12 pulse meter)
Summary of Contents for IPM 12
Page 47: ...Seite 47 DE...
Page 51: ...Seite 51 DE 11 4 COMO Zentralschmiersystem berwachung 11 Anschlussbeispiele Men struktur...
Page 53: ...Seite 53 DE...
Page 101: ...Page 101 EN...
Page 105: ...Page 105 EN 11 4 Overview COMO Lube System Monitoring 11 Connection example menu structure...
Page 107: ...Page 107 EN...