PGA 3 Input of setup values, Table 1 from 2
Step
Key
Function
1
Select main menu
Press
function key F1
In the main menu the cursor flashes in the addr. entry field (address of the IPM 12 to be selected).
2
Switchover of actual/setup value display to pulses/minute [P/min] or liters/minute [L/min]
Press
function key F4
The current actual and setup values of the measuring points are shown on the display in pulses/minute [P/min]. When key F4 is
pressed again the program jumps back to the display mode for liters/minute [L/min].
3
Select actual/setup value menu
Use the
numeric keypad
to enter the address of the IPM 12 pulse meter to be read out (e.g. Addr.1)
The actual/setup value menu is jumped to, measuring points 1 to 6.
4
Press the
next step function key
The actual/setup value menu is jumped to, measuring points 7 to 12
5
Select display menu
Press the
next step function key
The display menu is jumped to
6
Select code men
Press
function key F2
The code menu is jumped to
7
Use the
numeric keypad
to enter the code number
Press the ENTER key
he input menu is jumped to.
7.4 Input of setup values
7. Operating
4