![SKF IPM 12 Operating Instructions Manual Download Page 80](http://html1.mh-extra.com/html/skf/ipm-12/ipm-12_operating-instructions-manual_1287095080.webp)
Page 80
EN
PGA 3 Readout of actual/setup values
Step
TKey
Function
1
Select main menu
Press key
F1
In the main menu the cursor flashes in the addr. entry field (address of
the IMP 12
2
Enter the address of the IPM 12 pulse meter to be read out (e.g. Addr. 1)
via the
numeric keypad.
The readout menu is jumped to.
3
Display of current actual, setup and calibration values
(meas. points 1 to 6)
The current actual, setup and calibration values of the first six measuring
points of the IPM12 are shown on the display in pulses/minute [P/min].
4
Display of further actual, setup and calibration values
(meas. points 7 to 12)
Press the
next step function key
The current actual, setup and calibration values of measuring points 7 to
12 of the selected IPM12 are shown on the display in pulses/minute [P/min].
5
Alternatively: back to measuring points 1 to 6
Press the
previous step function key
The current actual, setup and calibration values of the first six measu-
ring points are shown on the display in pulses/minute [P/min].
6
Switchover of actual and setup value display to liters/minute [L/min]
Press
function key F4
The current actual and setup values of the measuring points are shown
on the display in liters/minute [L/min].
When key F4 is pressed again the program jumps back to the pulses/
minute [P/min] display mode.
7.2 PGA 3 programming and display unit
7.3 Readout of actual/setup values
The PGA 3 programming and display
unit does not affect the IMP12 pulse
meter’s monitoring function when it re-
ads out the actual or setup values. The
actual value is automatically updated.
In the programming mode (function key
F2 or F3) the data transfer to the selec-
ted IPM 12 is interrupted until the input
of data is completed (by saving).
An Ethernet data transfer is not possible
during this process.
TRM/816
F1
S1
S2
1
7. Operating
4
Summary of Contents for IPM 12